The main protection against electric shock is the “active” measure based on preventing the persistence of the electrical hazards limiting the time duration of the risk exposure to the electric contact. For the electrical risk assessment, the analysis of the risk exposure is treated by an innovative approach in analogy with collisions problems. Therefore, in practice the protection against the indirect contact in LV systems can be characterized as conventionally safe or probable and the same contact during the fault event can result prospected safe or fatal.

The main protection against electric shock is the “active” measure based on preventing the persistence of the electrical hazards limiting the time duration of the risk exposure to the electric contact. For the electrical risk assessment, the analysis of the risk exposure is treated by an innovative approach in analogy with collisions problems. Therefore, in practice the protection against the indirect contact in LV systems can be characterized as conventionally safe or probable and the same contact during the fault event can result prospected safe or fatal.

Collision Theory in Electric Shock Risk Assessment / Parise, Giuseppe; Parise, Luigi; Lombardi, Mara. - ELETTRONICO. - (2014), pp. 1-4. (Intervento presentato al convegno 2014 AEIT Annual Conference tenutosi a Trieste nel 18-19 September 2014) [10.1109/AEIT.2014.7002031].

Collision Theory in Electric Shock Risk Assessment

PARISE, Giuseppe;PARISE, LUIGI;LOMBARDI, MARA
2014

Abstract

The main protection against electric shock is the “active” measure based on preventing the persistence of the electrical hazards limiting the time duration of the risk exposure to the electric contact. For the electrical risk assessment, the analysis of the risk exposure is treated by an innovative approach in analogy with collisions problems. Therefore, in practice the protection against the indirect contact in LV systems can be characterized as conventionally safe or probable and the same contact during the fault event can result prospected safe or fatal.
2014
2014 AEIT Annual Conference
The main protection against electric shock is the “active” measure based on preventing the persistence of the electrical hazards limiting the time duration of the risk exposure to the electric contact. For the electrical risk assessment, the analysis of the risk exposure is treated by an innovative approach in analogy with collisions problems. Therefore, in practice the protection against the indirect contact in LV systems can be characterized as conventionally safe or probable and the same contact during the fault event can result prospected safe or fatal.
protection against electric shock; electrical risk; intersections theory; safety; risks assessment
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Collision Theory in Electric Shock Risk Assessment / Parise, Giuseppe; Parise, Luigi; Lombardi, Mara. - ELETTRONICO. - (2014), pp. 1-4. (Intervento presentato al convegno 2014 AEIT Annual Conference tenutosi a Trieste nel 18-19 September 2014) [10.1109/AEIT.2014.7002031].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/650032
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact