Power converters are complex devices subject to failures that can lead to undesired stops. For this reason, many fault tolerant topologies and strategies have been deeply studied, mainly focusing on improving the electromechanical behaviour of the reconfigured drive after the fault. However, it is also very important to evaluate the possible increase of power losses. In this paper a power loss analysis is performed on a current controlled three-phase inverter supplying a permanent magnet synchronous motor – just chosen as an example -, for all the operating modes, starting from the fault occurrence, until the faulty operation mode is established. This is particularly important because the effectiveness of a fault-tolerant control strategy depends on the possibility to maintain a continuous operation. The latter is ensured only if there is no such an increment of the losses that the survival of the component is at risk. The simulations are validated by means of experimental tests and the results are discussed. The method can be easily applied to other topologies and reconfiguration strategies.

Converter Power Loss Analysis in a Fault-Tolerant Permanent Magnet Synchronous Motor Drive / A., Stabile; J., Estima; Boccaletti, Chiara; A. J., Marques Cardoso. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - STAMPA. - 62:3(2015), pp. 1984-1996. [10.1109/TIE.2014.2385652]

Converter Power Loss Analysis in a Fault-Tolerant Permanent Magnet Synchronous Motor Drive

BOCCALETTI, Chiara;
2015

Abstract

Power converters are complex devices subject to failures that can lead to undesired stops. For this reason, many fault tolerant topologies and strategies have been deeply studied, mainly focusing on improving the electromechanical behaviour of the reconfigured drive after the fault. However, it is also very important to evaluate the possible increase of power losses. In this paper a power loss analysis is performed on a current controlled three-phase inverter supplying a permanent magnet synchronous motor – just chosen as an example -, for all the operating modes, starting from the fault occurrence, until the faulty operation mode is established. This is particularly important because the effectiveness of a fault-tolerant control strategy depends on the possibility to maintain a continuous operation. The latter is ensured only if there is no such an increment of the losses that the survival of the component is at risk. The simulations are validated by means of experimental tests and the results are discussed. The method can be easily applied to other topologies and reconfiguration strategies.
2015
loss measurements; switching loss; insulated gate bipolar transistors; diodes; fault tolerance; fault diagnosis; thermal stresses; inverters; permanent magnet machines; variable speed drives
01 Pubblicazione su rivista::01a Articolo in rivista
Converter Power Loss Analysis in a Fault-Tolerant Permanent Magnet Synchronous Motor Drive / A., Stabile; J., Estima; Boccaletti, Chiara; A. J., Marques Cardoso. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - STAMPA. - 62:3(2015), pp. 1984-1996. [10.1109/TIE.2014.2385652]
File allegati a questo prodotto
File Dimensione Formato  
Stabile_Converter_2015.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 3.65 MB
Formato Adobe PDF
3.65 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/645398
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 12
social impact