Neurosurgery aims to achieve maximal tumor resection while preserving neurological function. Tools such as neuronavigation, high-field intraoperative magnetic resonance imaging (iMRI), and intraoperative neurophysiological monitoring (IOM) have consistently helped to achieve this goal, but integration has often been difficult. Surgery of eloquent areas requires IOM, which in an operating theater equipped with high-field (1.5-T) iMRI could present several issues. To identify the electrodes types more suitable for IOM in a high-field iMRI operating theater by performing an experimental study on phantoms, to report our experience with platinum-iridium (Pt/Ir) electrodes during surgery, and to prove that integration between IOM with Pt/Ir electrodes and high-field iMRI is safe and reliable. Electrodes of different materials (gold, Pt/Ir, and stainless steel) were tested on jelly phantom and apples to evaluate their safety and compatibility. Subsequently, electrodes were tested on 5 healthy volunteers before being used on patients. None of the different electrodes presented thermal instability, and no damage to the volunteers' skin occurred. Stainless steel electrodes caused severe imaging distortion. Gold electrodes had no distortion, but their high cost makes their use in routine surgery unaffordable. Pt/Ir electrodes are significantly less expensive than gold electrodes and were completely safe, compatible, and suitable for use in an operating theater with high-field iMRI, providing excellent IOM and mild interference that did not affect the quality of intraoperative imaging. We suggest the use of Pt/Ir electrodes for IOM in 1.5-T iMRI suites. DTI, diffusion tensor imagingiMRI, intraoperative magnetic resonance imagingIOM, intraoperative neurophysiological monitoring.

Platinum-iridium subdermal magnetic resonance imaging-compatible needle electrodes are suitable for intraoperative neurophysiological monitoring during image-guided surgery with high-field intraoperative magnetic resonance imaging: an experimental study / Giancarlo, D'Andrea; Albina, Angelini; Camillo, Foresti; Familiari, Pietro; Emanuela, Caroli; Frati, Alessandro. - In: NEUROSURGERY. - ISSN 0148-396X. - STAMPA. - 10 Suppl 3:10(2014), pp. 387-392. [10.1227/neu.0000000000000432]

Platinum-iridium subdermal magnetic resonance imaging-compatible needle electrodes are suitable for intraoperative neurophysiological monitoring during image-guided surgery with high-field intraoperative magnetic resonance imaging: an experimental study.

FAMILIARI, PIETRO;FRATI, ALESSANDRO
2014

Abstract

Neurosurgery aims to achieve maximal tumor resection while preserving neurological function. Tools such as neuronavigation, high-field intraoperative magnetic resonance imaging (iMRI), and intraoperative neurophysiological monitoring (IOM) have consistently helped to achieve this goal, but integration has often been difficult. Surgery of eloquent areas requires IOM, which in an operating theater equipped with high-field (1.5-T) iMRI could present several issues. To identify the electrodes types more suitable for IOM in a high-field iMRI operating theater by performing an experimental study on phantoms, to report our experience with platinum-iridium (Pt/Ir) electrodes during surgery, and to prove that integration between IOM with Pt/Ir electrodes and high-field iMRI is safe and reliable. Electrodes of different materials (gold, Pt/Ir, and stainless steel) were tested on jelly phantom and apples to evaluate their safety and compatibility. Subsequently, electrodes were tested on 5 healthy volunteers before being used on patients. None of the different electrodes presented thermal instability, and no damage to the volunteers' skin occurred. Stainless steel electrodes caused severe imaging distortion. Gold electrodes had no distortion, but their high cost makes their use in routine surgery unaffordable. Pt/Ir electrodes are significantly less expensive than gold electrodes and were completely safe, compatible, and suitable for use in an operating theater with high-field iMRI, providing excellent IOM and mild interference that did not affect the quality of intraoperative imaging. We suggest the use of Pt/Ir electrodes for IOM in 1.5-T iMRI suites. DTI, diffusion tensor imagingiMRI, intraoperative magnetic resonance imagingIOM, intraoperative neurophysiological monitoring.
2014
intraoperative neurophysiological monitoring; intraoperative mri; platinum-iridium electrodes; brain tumors
01 Pubblicazione su rivista::01a Articolo in rivista
Platinum-iridium subdermal magnetic resonance imaging-compatible needle electrodes are suitable for intraoperative neurophysiological monitoring during image-guided surgery with high-field intraoperative magnetic resonance imaging: an experimental study / Giancarlo, D'Andrea; Albina, Angelini; Camillo, Foresti; Familiari, Pietro; Emanuela, Caroli; Frati, Alessandro. - In: NEUROSURGERY. - ISSN 0148-396X. - STAMPA. - 10 Suppl 3:10(2014), pp. 387-392. [10.1227/neu.0000000000000432]
File allegati a questo prodotto
File Dimensione Formato  
neurosurgery platinum iridium.pdf

solo gestori archivio

Note: D'Andrea_Platinum-Iridium Subdermal Magnetic Resonance_2014
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 302 kB
Formato Adobe PDF
302 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/643856
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 11
social impact