In this contribution we will report on the progress of the design of the readout and data acquisition system being developed for triple-GEM detectors which will be installed in the forward region (1.5 < |η| < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, expected in the period 2017-2018. The system will be designed to take full advantage of current generic developments introduced for the LHC upgrades. The current design is based on the use of CERN GLIB boards hosted in micro-TCA crates for the off-detector electronics and the Versatile Link with the GBT chipset to link the front-end electronics to the GLIB boards. In this contribution we will describe the physics goals, the hardware architectures and report on the expected performance of the CMS GEM readout system, including preliminary timing resolution simulations. © CERN 2014.

Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer / Abbaneo, D.; Abbrescia, M.; Akl, M. A.; Ahmed, W.; Armaingaud, C.; Aspell, P.; Assran, Y.; Bally, S.; Ban, Y.; Banerjee, S.; Barria, P.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Cai, J.; Calabria, C.; Castaneda, A.; Cauwenbergh, S.; Celik, A.; Christiansen, J.; Colafranceschi, S.; Colaleo, A.; Garcia, A. C.; Dabrowski, M.; De, Lentdecker; De, Oliveira; De, Robertis; G., Dildick; S., Ferry; S., Flanagan; W., Gilmore; J., Guilloux; F., Gutierrez; A., Hoepfner; K., Hohlmann; M., Kamon; T., Karchin; P. E., Khotilovich; V., Korntheuer; M., Krutelyov; S., Lenzi; T., Loddo; F., Maerschalk; T., Magazzu; G., Maggi; M., Maghrbi; Y., Marchioro; A., Marinov; A., Mazumdar; N., Merlin; J. A., Mukhopadhyay; S., Nuzzo; S., Oliveri; E., Philipps; B., Piccolo; D., Postema; H., Radi; A., Radogna; R., Raffone; G., Ranieri; A., Rodrigues; A., Ropelewski; L., Safonov; A., Sakharov; A., Salva; Saviano, Giovanna; G., Sharma; A., Talvitie; J., Tatarinov; A., Teng; H., Turini; N., Tuuva; T., Twigger; J., Tytgat; M., Stenis; M. V., Verhagen; E., Yang; Y., Zaganidis; N., Zenoni. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 9:3(2014). [10.1088/1748-0221/9/03/C03052]

Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

SAVIANO, Giovanna;
2014

Abstract

In this contribution we will report on the progress of the design of the readout and data acquisition system being developed for triple-GEM detectors which will be installed in the forward region (1.5 < |η| < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, expected in the period 2017-2018. The system will be designed to take full advantage of current generic developments introduced for the LHC upgrades. The current design is based on the use of CERN GLIB boards hosted in micro-TCA crates for the off-detector electronics and the Versatile Link with the GBT chipset to link the front-end electronics to the GLIB boards. In this contribution we will describe the physics goals, the hardware architectures and report on the expected performance of the CMS GEM readout system, including preliminary timing resolution simulations. © CERN 2014.
2014
Data acquisition circuits, Electronic detector readout concepts (gas; liquid); Detector circuits, Particle spectrometers, Readout systems Data acquisition circuit, Data acquisition system, Electronic detectors, Front end electronics, Hardware architecture, Muon spectrometer, Off-detector electronics, Timing resolutions
01 Pubblicazione su rivista::01a Articolo in rivista
Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer / Abbaneo, D.; Abbrescia, M.; Akl, M. A.; Ahmed, W.; Armaingaud, C.; Aspell, P.; Assran, Y.; Bally, S.; Ban, Y.; Banerjee, S.; Barria, P.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Cai, J.; Calabria, C.; Castaneda, A.; Cauwenbergh, S.; Celik, A.; Christiansen, J.; Colafranceschi, S.; Colaleo, A.; Garcia, A. C.; Dabrowski, M.; De, Lentdecker; De, Oliveira; De, Robertis; G., Dildick; S., Ferry; S., Flanagan; W., Gilmore; J., Guilloux; F., Gutierrez; A., Hoepfner; K., Hohlmann; M., Kamon; T., Karchin; P. E., Khotilovich; V., Korntheuer; M., Krutelyov; S., Lenzi; T., Loddo; F., Maerschalk; T., Magazzu; G., Maggi; M., Maghrbi; Y., Marchioro; A., Marinov; A., Mazumdar; N., Merlin; J. A., Mukhopadhyay; S., Nuzzo; S., Oliveri; E., Philipps; B., Piccolo; D., Postema; H., Radi; A., Radogna; R., Raffone; G., Ranieri; A., Rodrigues; A., Ropelewski; L., Safonov; A., Sakharov; A., Salva; Saviano, Giovanna; G., Sharma; A., Talvitie; J., Tatarinov; A., Teng; H., Turini; N., Tuuva; T., Twigger; J., Tytgat; M., Stenis; M. V., Verhagen; E., Yang; Y., Zaganidis; N., Zenoni. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 9:3(2014). [10.1088/1748-0221/9/03/C03052]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/630136
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact