In this paper the ability of four radar sensors in detecting breath activity has been tested. In particular, range gating UWB, CMOS UWB, CW phase detecting, and FMCW radars have taken into account. Considering a realistic scenario, the radar antenna has been pointed towards the thorax of a breathing subject and the recorded signals have been compared with those of a piezoelectric belt placed around the thorax. Then the ability of the radars in detecting small movements has been tested by means of an oscillating copper plate placed at various distances from the radar antenna. All the considered radars were able to detect the plate movements with a distance-dependent resolution. © 2014 SPIE.

Comparison between UWB and CW radar sensors for breath activity monitoring / Pisa, Stefano; Bernardi, Paolo Italo; Cicchetti, Renato; Roberto, Giusto; Pittella, Erika; Piuzzi, Emanuele; Testa, Orlandino. - STAMPA. - 9077:(2014), p. 907711. (Intervento presentato al convegno Radar Sensor Technology XVIII tenutosi a Baltimore, MD nel 5 May 2014 through 7 May 2014) [10.1117/12.2049521].

Comparison between UWB and CW radar sensors for breath activity monitoring

PISA, Stefano;BERNARDI, Paolo Italo;CICCHETTI, Renato;PITTELLA, ERIKA;PIUZZI, Emanuele;TESTA, Orlandino
2014

Abstract

In this paper the ability of four radar sensors in detecting breath activity has been tested. In particular, range gating UWB, CMOS UWB, CW phase detecting, and FMCW radars have taken into account. Considering a realistic scenario, the radar antenna has been pointed towards the thorax of a breathing subject and the recorded signals have been compared with those of a piezoelectric belt placed around the thorax. Then the ability of the radars in detecting small movements has been tested by means of an oscillating copper plate placed at various distances from the radar antenna. All the considered radars were able to detect the plate movements with a distance-dependent resolution. © 2014 SPIE.
2014
Radar Sensor Technology XVIII
fmcw radar.; cw radar; uwb radar; breath activity; fmcw radar
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Comparison between UWB and CW radar sensors for breath activity monitoring / Pisa, Stefano; Bernardi, Paolo Italo; Cicchetti, Renato; Roberto, Giusto; Pittella, Erika; Piuzzi, Emanuele; Testa, Orlandino. - STAMPA. - 9077:(2014), p. 907711. (Intervento presentato al convegno Radar Sensor Technology XVIII tenutosi a Baltimore, MD nel 5 May 2014 through 7 May 2014) [10.1117/12.2049521].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/625582
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact