On-chip optical detection of chemiluminescent reactions is presented. The device is based on the integration of thin film hydrogenated amorphous silicon photosensors on a functionalized glass substrate ensuring both a good optical coupling and an optimal separation between biological or chemical reagents and the sensing elements. The sensor has been characterized and optimized using the chemiluminescent system composed by the enzyme horseradish peroxidase (HRP) and luminol/peroxide/enhancer cocktail. The detectability of HRP is at the attomole level with a sensitivity of 1.46 fA/fg. Experiments, involving the detection of immobilized bio-specific probes on the functionalized surface have been performed both in bulk and microfluidics regime, proving the ability of the system to effectively detect chemiluminescent reactions and their kinetics. In particular, results achieved using conventional polydimethylsiloxane microfluidics for samples and reagents handling confirmed the good detection capabilities of the proposed system.

Microfluidic Chip With Integrated a-Si: H Photodiodes for Chemiluminescence-Based Bioassays / Caputo, Domenico; DE CESARE, Giampiero; Luisa Stella, Dolci; Mara, Mirasoli; Nascetti, Augusto; Aldo, Roda; Scipinotti, Riccardo. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - 13:7(2013), pp. 2595-2602. [10.1109/jsen.2013.2256889]

Microfluidic Chip With Integrated a-Si: H Photodiodes for Chemiluminescence-Based Bioassays

CAPUTO, Domenico;DE CESARE, Giampiero;NASCETTI, Augusto;SCIPINOTTI, RICCARDO
2013

Abstract

On-chip optical detection of chemiluminescent reactions is presented. The device is based on the integration of thin film hydrogenated amorphous silicon photosensors on a functionalized glass substrate ensuring both a good optical coupling and an optimal separation between biological or chemical reagents and the sensing elements. The sensor has been characterized and optimized using the chemiluminescent system composed by the enzyme horseradish peroxidase (HRP) and luminol/peroxide/enhancer cocktail. The detectability of HRP is at the attomole level with a sensitivity of 1.46 fA/fg. Experiments, involving the detection of immobilized bio-specific probes on the functionalized surface have been performed both in bulk and microfluidics regime, proving the ability of the system to effectively detect chemiluminescent reactions and their kinetics. In particular, results achieved using conventional polydimethylsiloxane microfluidics for samples and reagents handling confirmed the good detection capabilities of the proposed system.
2013
amorphous silicon sensors; chemiluminescence; sensor systems and applications
01 Pubblicazione su rivista::01a Articolo in rivista
Microfluidic Chip With Integrated a-Si: H Photodiodes for Chemiluminescence-Based Bioassays / Caputo, Domenico; DE CESARE, Giampiero; Luisa Stella, Dolci; Mara, Mirasoli; Nascetti, Augusto; Aldo, Roda; Scipinotti, Riccardo. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - 13:7(2013), pp. 2595-2602. [10.1109/jsen.2013.2256889]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/621779
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 34
social impact