In this chapter, an optoelectronic Lab-on-Chip system for DNA amplification integrating a polydimethylsiloxane microfluidic structure with indium tin oxide heaters on a 5 × 5 cm2 microscope glass slide is presented. The microfluidic structure comprises a channel for the fluid handling and a reaction chamber for the polymerase chain reaction (PCR). Two lateral heaters, located at the inlet and outlet positions of the chamber, actuate the valves and allow the chamber isolation, while the last one, positioned below the chamber, is dedicated to the PCR thermal cycle. In order to optimize heaters and valves geometry, the temperature distribution over the heaters and the membrane valve deformation have been studied using the commercial software COMSOL Multiphysics. The microfluidic structure has been fabricated by using soft lithography techniques on one side of the glass substrate, while the thin film heaters were deposited and patterned on the opposite glass side. Experiments show that valve activation begins around 60 C, and complete closure is observed around to 100 C, without any loss of liquid from the chamber. © 2014 Springer International Publishing Switzerland.

Thermally actuated microfluidic system for polymerase chain reaction applications / Caputo, Domenico; DE CESARE, Giampiero; A., De Pastina; P., Romano; Scipinotti, Riccardo; N., Stasio; Nascetti, Augusto. - STAMPA. - 268 LNEE:(2014), pp. 23-27. (Intervento presentato al convegno 17th National Conference on Sensors and Microsystems tenutosi a Brescia nel 5 February 2013 through 7 February 2013) [10.1007/978-3-319-00684-0-5].

Thermally actuated microfluidic system for polymerase chain reaction applications

CAPUTO, Domenico;DE CESARE, Giampiero;SCIPINOTTI, RICCARDO;NASCETTI, Augusto
2014

Abstract

In this chapter, an optoelectronic Lab-on-Chip system for DNA amplification integrating a polydimethylsiloxane microfluidic structure with indium tin oxide heaters on a 5 × 5 cm2 microscope glass slide is presented. The microfluidic structure comprises a channel for the fluid handling and a reaction chamber for the polymerase chain reaction (PCR). Two lateral heaters, located at the inlet and outlet positions of the chamber, actuate the valves and allow the chamber isolation, while the last one, positioned below the chamber, is dedicated to the PCR thermal cycle. In order to optimize heaters and valves geometry, the temperature distribution over the heaters and the membrane valve deformation have been studied using the commercial software COMSOL Multiphysics. The microfluidic structure has been fabricated by using soft lithography techniques on one side of the glass substrate, while the thin film heaters were deposited and patterned on the opposite glass side. Experiments show that valve activation begins around 60 C, and complete closure is observed around to 100 C, without any loss of liquid from the chamber. © 2014 Springer International Publishing Switzerland.
2014
17th National Conference on Sensors and Microsystems
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Thermally actuated microfluidic system for polymerase chain reaction applications / Caputo, Domenico; DE CESARE, Giampiero; A., De Pastina; P., Romano; Scipinotti, Riccardo; N., Stasio; Nascetti, Augusto. - STAMPA. - 268 LNEE:(2014), pp. 23-27. (Intervento presentato al convegno 17th National Conference on Sensors and Microsystems tenutosi a Brescia nel 5 February 2013 through 7 February 2013) [10.1007/978-3-319-00684-0-5].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/620788
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact