Background Catheter ablation is a common and effective procedure for addressing atrial fibrillation (AF) refractory to antiarrhythmic drugs. AF can be terminated in 3 modes: (1) directly into sinus rhythm (SR); (2) evolving into regular atrial tachycardia (AT) and subsequently into SR; and (3) after direct current (DC) cardioversion if AF persists. Scarce data are available on the relationship between clinical outcomes and termination mode after 1 catheter ablation. Objective The purpose of this study was to evaluate for the first time the association between 1-year ablation efficacy and termination mode after repeated catheter ablations in patients presenting with persistent or long-standing persistent AF. Methods This prospective study involved 400 consecutive patients (age 62.7 ± 7.2 years) who underwent catheter ablation for drug-refractory persistent AF (4.6 ± 2.4 months) using a stepwise ablation approach. Results AF was terminated by radiofrequency application directly into SR

Background: Catheter ablation is a common and effective procedure for addressing atrial fibrillation (AF) refractory to antiarrhythmic drugs. AF can be terminated in 3 modes: (1) directly into sinus rhythm (SR); (2) evolving into regular atrial tachycardia (AT) and subsequently into SR; and (3) after direct current (DC) cardioversion if AF persists. Scarce data are available on the relationship between clinical outcomes and termination mode after 1 catheter ablation. Objective: The purpose of this study was to evaluate for the first time the association between 1-year ablation efficacy and termination mode after repeated catheter ablations in patients presenting with persistent or long-standing persistent AF. Methods: This prospective study involved 400 consecutive patients (age 62.7 ± 7.2 years) who underwent catheter ablation for drug-refractory persistent AF (4.6 ± 2.4 months) using a stepwise ablation approach. Results: AF was terminated by radiofrequency application directly into SR in 135 patients; passing through AT into SR in 195 patients; and through DC cardioversion in 70 patients. After 1-year follow-up with repeated Holter monitoring, the percentages of SR maintenance were 72.6%, 80.0%, and 28.6%, respectively (P < .001). Compared with the subjects who were converted directly into SR, the adjusted hazard ratios (HRs) of SR maintenance were significantly lower for those who required DC cardioversion (HR = 0.54; P < .001) and higher for those converted through AT (HR = 1.69; P = .027). The latter association was even stronger in the 104 subjects who required a second procedure (HR = 6.25; P = .001). Conclusion: Termination of AF through AT during catheter ablation was more effective than both DC shock and direct SR in maintaining stable SR 1 year after both the first and the second procedures. © 2014 Heart Rhythm Society.

Impact of atrial fibrillation termination mode during catheter ablation procedure on maintenance of sinus rhythm / Massimiliano, Faustino; Carmine, Pizzi; Donato, Capuzzi; Tullio, Agricola; Grazia Maria, Costa; Maria Elena, Flacco; Marzuillo, Carolina; Manuela, Nocciolini; Lorenzo, Capasso; Lamberto, Manzoli. - In: HEART RHYTHM. - ISSN 1547-5271. - 11:9(2014), pp. 1528-1535. [10.1016/j.hrthm.2014.05.025]

Impact of atrial fibrillation termination mode during catheter ablation procedure on maintenance of sinus rhythm

MARZUILLO, CAROLINA;
2014

Abstract

Background Catheter ablation is a common and effective procedure for addressing atrial fibrillation (AF) refractory to antiarrhythmic drugs. AF can be terminated in 3 modes: (1) directly into sinus rhythm (SR); (2) evolving into regular atrial tachycardia (AT) and subsequently into SR; and (3) after direct current (DC) cardioversion if AF persists. Scarce data are available on the relationship between clinical outcomes and termination mode after 1 catheter ablation. Objective The purpose of this study was to evaluate for the first time the association between 1-year ablation efficacy and termination mode after repeated catheter ablations in patients presenting with persistent or long-standing persistent AF. Methods This prospective study involved 400 consecutive patients (age 62.7 ± 7.2 years) who underwent catheter ablation for drug-refractory persistent AF (4.6 ± 2.4 months) using a stepwise ablation approach. Results AF was terminated by radiofrequency application directly into SR
2014
Background: Catheter ablation is a common and effective procedure for addressing atrial fibrillation (AF) refractory to antiarrhythmic drugs. AF can be terminated in 3 modes: (1) directly into sinus rhythm (SR); (2) evolving into regular atrial tachycardia (AT) and subsequently into SR; and (3) after direct current (DC) cardioversion if AF persists. Scarce data are available on the relationship between clinical outcomes and termination mode after 1 catheter ablation. Objective: The purpose of this study was to evaluate for the first time the association between 1-year ablation efficacy and termination mode after repeated catheter ablations in patients presenting with persistent or long-standing persistent AF. Methods: This prospective study involved 400 consecutive patients (age 62.7 ± 7.2 years) who underwent catheter ablation for drug-refractory persistent AF (4.6 ± 2.4 months) using a stepwise ablation approach. Results: AF was terminated by radiofrequency application directly into SR in 135 patients; passing through AT into SR in 195 patients; and through DC cardioversion in 70 patients. After 1-year follow-up with repeated Holter monitoring, the percentages of SR maintenance were 72.6%, 80.0%, and 28.6%, respectively (P < .001). Compared with the subjects who were converted directly into SR, the adjusted hazard ratios (HRs) of SR maintenance were significantly lower for those who required DC cardioversion (HR = 0.54; P < .001) and higher for those converted through AT (HR = 1.69; P = .027). The latter association was even stronger in the 104 subjects who required a second procedure (HR = 6.25; P = .001). Conclusion: Termination of AF through AT during catheter ablation was more effective than both DC shock and direct SR in maintaining stable SR 1 year after both the first and the second procedures. © 2014 Heart Rhythm Society.
dc shock cardioversion; atrial fibrillation; catheter ablation; atrial tachycardia; prognosis
01 Pubblicazione su rivista::01a Articolo in rivista
Impact of atrial fibrillation termination mode during catheter ablation procedure on maintenance of sinus rhythm / Massimiliano, Faustino; Carmine, Pizzi; Donato, Capuzzi; Tullio, Agricola; Grazia Maria, Costa; Maria Elena, Flacco; Marzuillo, Carolina; Manuela, Nocciolini; Lorenzo, Capasso; Lamberto, Manzoli. - In: HEART RHYTHM. - ISSN 1547-5271. - 11:9(2014), pp. 1528-1535. [10.1016/j.hrthm.2014.05.025]
File allegati a questo prodotto
File Dimensione Formato  
Manzoli L Heart Rhythm 2014.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 518.79 kB
Formato Adobe PDF
518.79 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/609983
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact