In this study, a Whelk-O1 chiral stationary phase immobilized on 2.5 μm silica particles was employed in nanoLC. Two nanocolumns (180 and 250 mm long, 75 μm id) with a single polymeric organic monolithic outlet frit were packed under high-pressure ultrasonic-assisted packing procedure. The monolithic outlet frit was prepared by thermal polymerization of methacrylate-based monomers affording high-mechanical stability and high-pressure resistance. Very efficient enantioseparations with more than 70 000 plates/m were achieved in normal phase mode by eluting (+/-) acenaphthenol. Nanocolumns were also tested in RP mode by using on-line MS detection with nano-spray ESI ion source. Kinetic performances of columns in RP mode were comparable to those in normal phase-conditions

Toward enantioselective nano ultrahigh-performance liquid chromatography with Whelk-O1 chiral stationary phase / Ciogli, Alessia; Pierri, Giuseppe; Kotoni, Dorina; A., Cavazzini; L., Botta; Villani, Claudio; J., Kocergin; Gasparrini, Francesco. - In: ELECTROPHORESIS. - ISSN 0173-0835. - STAMPA. - 35:(2014), pp. 2819-2823. [10.1002/elps.201400240]

Toward enantioselective nano ultrahigh-performance liquid chromatography with Whelk-O1 chiral stationary phase

CIOGLI, Alessia;PIERRI, GIUSEPPE;KOTONI, DORINA;VILLANI, Claudio;GASPARRINI, Francesco
2014

Abstract

In this study, a Whelk-O1 chiral stationary phase immobilized on 2.5 μm silica particles was employed in nanoLC. Two nanocolumns (180 and 250 mm long, 75 μm id) with a single polymeric organic monolithic outlet frit were packed under high-pressure ultrasonic-assisted packing procedure. The monolithic outlet frit was prepared by thermal polymerization of methacrylate-based monomers affording high-mechanical stability and high-pressure resistance. Very efficient enantioseparations with more than 70 000 plates/m were achieved in normal phase mode by eluting (+/-) acenaphthenol. Nanocolumns were also tested in RP mode by using on-line MS detection with nano-spray ESI ion source. Kinetic performances of columns in RP mode were comparable to those in normal phase-conditions
2014
Enantioselective near-UHPLC, HRMS detection, Nano chiral columns
01 Pubblicazione su rivista::01a Articolo in rivista
Toward enantioselective nano ultrahigh-performance liquid chromatography with Whelk-O1 chiral stationary phase / Ciogli, Alessia; Pierri, Giuseppe; Kotoni, Dorina; A., Cavazzini; L., Botta; Villani, Claudio; J., Kocergin; Gasparrini, Francesco. - In: ELECTROPHORESIS. - ISSN 0173-0835. - STAMPA. - 35:(2014), pp. 2819-2823. [10.1002/elps.201400240]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/605603
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact