Background and Purpose: Treatment of patients with prostate cancer has evolved considerably in the last decade, especially in terms of minimization of the negative impacts on erectile function and continence to ensure good quality of life for treated patients. New surgical devices, such as dissectors and hemostatic scalpels, allow precise definition of the surgical field with finer dissection of the anatomic structures, with subsequent reductions in operative times and better oncologic and functional outcomes. Although monopolar scissors (MS) are still widely used, radiofrequency (RF) and ultrasound (US) scalpels have been introduced recently in laparoscopic radical prostatectomy (LRP). Despite the widespread use of these scalpels, however, few studies have compared these devices in terms of oncologic and functional outcomes after radical prostatectomy. The present study aimed to prospectively assess the impact of MS, RF, and US scalpels on margin status at apex, and recovery of urinar

Abstract Background and Purpose: Treatment of patients with prostate cancer has evolved considerably in the last decade, especially in terms of minimization of the negative impacts on erectile function and continence to ensure good quality of life for treated patients. New surgical devices, such as dissectors and hemostatic scalpels, allow precise definition of the surgical field with finer dissection of the anatomic structures, with subsequent reductions in operative times and better oncologic and functional outcomes. Although monopolar scissors (MS) are still widely used, radiofrequency (RF) and ultrasound (US) scalpels have been introduced recently in laparoscopic radical prostatectomy (LRP). Despite the widespread use of these scalpels, however, few studies have compared these devices in terms of oncologic and functional outcomes after radical prostatectomy. The present study aimed to prospectively assess the impact of MS, RF, and US scalpels on margin status at apex, and recovery of urinary continence and erectile function in patients undergoing extraperitoneal LRP. Patients and Methods: A total of 150 men were prospectively enrolled between September 2009 and April 2013 and postoperatively evaluated for continence and clinical factors. Results: There were no differences in terms of operative times (P=0.9433), blood loss (P=0.9681), apical margin positivity (P=0.3965) or postoperative hospital stay (P=0.9257) among the groups. Moreover, no differences in the functional outcome scores, as evaluated by the International Consultation on Incontinence self-administered Questionnaire, at 1, 3, and 6 months postsurgery were observed. Conclusion: Our study represents the first evaluation of continence recovery in LRP with respect to different devices used for prostatic apex dissection. We found that the oncologic, functional, and operative outcomes were similar between these different devices during LRP, with no scalpel demonstrating superiority in continence recovery.

Are Early Continence Recovery and Oncologic Outcomes Influenced by Use of Different Devices in Prostatic Apex Dissection During Laparoscopic Radical Prostatectomy? / Pastore, ANTONIO LUIGI; Palleschi, Giovanni; Aurel, Messas; Fuschi, Andrea; Alessandro, Zucchi; Elisabetta, Costantini; Silvestri, Luigi; Petrozza, Vincenzo; Carbone, Antonio. - In: JOURNAL OF ENDOUROLOGY. - ISSN 0892-7790. - STAMPA. - 28:11(2014), pp. 1313-1319. [10.1089/end.2014.0255]

Are Early Continence Recovery and Oncologic Outcomes Influenced by Use of Different Devices in Prostatic Apex Dissection During Laparoscopic Radical Prostatectomy?

PASTORE, ANTONIO LUIGI;PALLESCHI, GIOVANNI;Andrea Fuschi;SILVESTRI, LUIGI;PETROZZA, Vincenzo;CARBONE, Antonio
2014

Abstract

Background and Purpose: Treatment of patients with prostate cancer has evolved considerably in the last decade, especially in terms of minimization of the negative impacts on erectile function and continence to ensure good quality of life for treated patients. New surgical devices, such as dissectors and hemostatic scalpels, allow precise definition of the surgical field with finer dissection of the anatomic structures, with subsequent reductions in operative times and better oncologic and functional outcomes. Although monopolar scissors (MS) are still widely used, radiofrequency (RF) and ultrasound (US) scalpels have been introduced recently in laparoscopic radical prostatectomy (LRP). Despite the widespread use of these scalpels, however, few studies have compared these devices in terms of oncologic and functional outcomes after radical prostatectomy. The present study aimed to prospectively assess the impact of MS, RF, and US scalpels on margin status at apex, and recovery of urinar
2014
Abstract Background and Purpose: Treatment of patients with prostate cancer has evolved considerably in the last decade, especially in terms of minimization of the negative impacts on erectile function and continence to ensure good quality of life for treated patients. New surgical devices, such as dissectors and hemostatic scalpels, allow precise definition of the surgical field with finer dissection of the anatomic structures, with subsequent reductions in operative times and better oncologic and functional outcomes. Although monopolar scissors (MS) are still widely used, radiofrequency (RF) and ultrasound (US) scalpels have been introduced recently in laparoscopic radical prostatectomy (LRP). Despite the widespread use of these scalpels, however, few studies have compared these devices in terms of oncologic and functional outcomes after radical prostatectomy. The present study aimed to prospectively assess the impact of MS, RF, and US scalpels on margin status at apex, and recovery of urinary continence and erectile function in patients undergoing extraperitoneal LRP. Patients and Methods: A total of 150 men were prospectively enrolled between September 2009 and April 2013 and postoperatively evaluated for continence and clinical factors. Results: There were no differences in terms of operative times (P=0.9433), blood loss (P=0.9681), apical margin positivity (P=0.3965) or postoperative hospital stay (P=0.9257) among the groups. Moreover, no differences in the functional outcome scores, as evaluated by the International Consultation on Incontinence self-administered Questionnaire, at 1, 3, and 6 months postsurgery were observed. Conclusion: Our study represents the first evaluation of continence recovery in LRP with respect to different devices used for prostatic apex dissection. We found that the oncologic, functional, and operative outcomes were similar between these different devices during LRP, with no scalpel demonstrating superiority in continence recovery.
01 Pubblicazione su rivista::01a Articolo in rivista
Are Early Continence Recovery and Oncologic Outcomes Influenced by Use of Different Devices in Prostatic Apex Dissection During Laparoscopic Radical Prostatectomy? / Pastore, ANTONIO LUIGI; Palleschi, Giovanni; Aurel, Messas; Fuschi, Andrea; Alessandro, Zucchi; Elisabetta, Costantini; Silvestri, Luigi; Petrozza, Vincenzo; Carbone, Antonio. - In: JOURNAL OF ENDOUROLOGY. - ISSN 0892-7790. - STAMPA. - 28:11(2014), pp. 1313-1319. [10.1089/end.2014.0255]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/593035
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
social impact