Many modern molecular imaging techniques, based on radiopharmaceuticals, can take advantage of sophisticated devices but are still based on the scintillation detector mechanism proposed by Anger. These devices can perform with millimeter spatial resolution and high detection efficiency, but the final performance is strongly affected by the algorithm used for the scintillation position detection. In this work, a detailed comparison of the effect on the imaging performances of three new position detection algorithms, in terms of spatial resolution, detection linearity and useful Field of View is performed on a prototype gamma detector. The detector, built by the authors, is based on a continuous LaBr3:Ce scintillation crystal coupled to an Hamamatsu MA-PMT H8500 and a single anode readout electronics. The experimental data are obtained scanning the detector surface with a Tc99m collimated source (0.4 mm φ) at 1.5 mm step. The overall imaging performances of the device are also tested by mean of a bar phantom. We conclude that the Anger-like algorithms give a 50% uFoV with a 1.30 mm ±0.05 mm spatial resolution while the proposed algorithms give a 80% uFoV and 1.10 mm ±0.06 mm spatial resolution.© 2013 IOP Publishing Ltd and Sissa Medialab srl.

Study of position reconstruction of a LaBr3: Ce continuous scintillation crystal for medical applications / A., Fabbri; D., Sacco; P., Bennati; A., Baroncelli; M., Galasso; Cinti, Maria Nerina; Pellegrini, Rosanna; Pani, Roberto; V. O., Cencelli. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 8:12(2013), pp. art. P12010-1-art. P12010-16. [10.1088/1748-0221/8/12/p12010]

Study of position reconstruction of a LaBr3: Ce continuous scintillation crystal for medical applications

CINTI, Maria Nerina;PELLEGRINI, Rosanna;PANI, Roberto;
2013

Abstract

Many modern molecular imaging techniques, based on radiopharmaceuticals, can take advantage of sophisticated devices but are still based on the scintillation detector mechanism proposed by Anger. These devices can perform with millimeter spatial resolution and high detection efficiency, but the final performance is strongly affected by the algorithm used for the scintillation position detection. In this work, a detailed comparison of the effect on the imaging performances of three new position detection algorithms, in terms of spatial resolution, detection linearity and useful Field of View is performed on a prototype gamma detector. The detector, built by the authors, is based on a continuous LaBr3:Ce scintillation crystal coupled to an Hamamatsu MA-PMT H8500 and a single anode readout electronics. The experimental data are obtained scanning the detector surface with a Tc99m collimated source (0.4 mm φ) at 1.5 mm step. The overall imaging performances of the device are also tested by mean of a bar phantom. We conclude that the Anger-like algorithms give a 50% uFoV with a 1.30 mm ±0.05 mm spatial resolution while the proposed algorithms give a 80% uFoV and 1.10 mm ±0.06 mm spatial resolution.© 2013 IOP Publishing Ltd and Sissa Medialab srl.
2013
image reconstruction in medical imaging; coronary ct angiography (cta); gamma camera; spect; pet pet/ct; medical-image reconstruction methods and algorithms; computer-aided software
01 Pubblicazione su rivista::01a Articolo in rivista
Study of position reconstruction of a LaBr3: Ce continuous scintillation crystal for medical applications / A., Fabbri; D., Sacco; P., Bennati; A., Baroncelli; M., Galasso; Cinti, Maria Nerina; Pellegrini, Rosanna; Pani, Roberto; V. O., Cencelli. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - ELETTRONICO. - 8:12(2013), pp. art. P12010-1-art. P12010-16. [10.1088/1748-0221/8/12/p12010]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/562751
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 8
social impact