Objective: Cerebral vasomotor reactivity (VMR) and coherence of resting state electroencephalographic (EEG) rhythms are impaired in Alzheimer's disease (AD) patients. Here we tested the hypothesis that these two variables could be related. Methods: We investigated VMR and coherence of resting state EEG rhythms in nine normal elderly (Nold) and in 10 amnesic mild cognitive impairment (MCI) subjects. Resting state eyes-closed EEG data were recorded at baseline pre-CO2 (ambient air, 2 min), during 7% CO2/air mixture inhalation (hypercapnia, 90 s) and post-CO2 (ambient air, 2 min) conditions. Simultaneous frontal bilateral near-infrared spectroscopy (NIRS) was performed to assess VMR by cortical oxy-and deoxy-haemoglobin concentration changes. EEG coherence across all electrodes was computed at delta (2-4 Hz), theta (4-8 Hz), alpha 1 (8-10.5 Hz), alpha 2 (10.5-13 Hz), beta 1 (13-20 Hz), beta 2 (20-30 Hz) and gamma (30-40 Hz) bands. Results: In Nold subjects, 'total coherence' of EEG across all frequency bands and electrode pairs decreased during hypercapnia, with full recovery during post-CO2. Total coherence resulted lower in pre-CO2 and post-CO2 and presented poor reactivity during CO2 inhalation in MCI patients compared with Nold subjects. Hypercapnia increased oxy-haemoglobin and decreased deoxy-haemoglobin concentrations in both groups. Furthermore, the extent of changes in these variables during CO2 challenge was correlated with the EEG coherence, as a reflection of neurovascular coupling. Conclusions: Hypercapnia induced normal frontal VMR that was detected by NIRS in both Nold and amnesic MCI groups, while it produced a reactivity of global functional coupling of resting state EEG rhythms only in the Nold group. Significance: In amnesic MCI patients, global EEG functional coupling is basically low in amplitude and does not react to hypercapnia. (C) 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Hypercapnia affects the functional coupling of resting state electroencephalographic rhythms and cerebral haemodynamics in healthy elderly subjects and in patients with amnestic mild cognitive impairment / Babiloni, Claudio; Fabrizio, Vecchio; Riccardo, Altavilla; Francesco, Tibuzzi; Lizio, Roberta; Claudia, Altamura; Paola, Palazzo; Paola, Maggio; Francesca, Ursini; Matilde, Ercolani; Andrea, Soricelli; Noce, Giuseppe; Paolo Maria, Rossini; Fabrizio, Vernieri. - In: CLINICAL NEUROPHYSIOLOGY. - ISSN 1388-2457. - 125:4(2014), pp. 685-693. [10.1016/j.clinph.2013.10.002]

Hypercapnia affects the functional coupling of resting state electroencephalographic rhythms and cerebral haemodynamics in healthy elderly subjects and in patients with amnestic mild cognitive impairment

BABILONI, CLAUDIO;LIZIO, ROBERTA;NOCE, GIUSEPPE;
2014

Abstract

Objective: Cerebral vasomotor reactivity (VMR) and coherence of resting state electroencephalographic (EEG) rhythms are impaired in Alzheimer's disease (AD) patients. Here we tested the hypothesis that these two variables could be related. Methods: We investigated VMR and coherence of resting state EEG rhythms in nine normal elderly (Nold) and in 10 amnesic mild cognitive impairment (MCI) subjects. Resting state eyes-closed EEG data were recorded at baseline pre-CO2 (ambient air, 2 min), during 7% CO2/air mixture inhalation (hypercapnia, 90 s) and post-CO2 (ambient air, 2 min) conditions. Simultaneous frontal bilateral near-infrared spectroscopy (NIRS) was performed to assess VMR by cortical oxy-and deoxy-haemoglobin concentration changes. EEG coherence across all electrodes was computed at delta (2-4 Hz), theta (4-8 Hz), alpha 1 (8-10.5 Hz), alpha 2 (10.5-13 Hz), beta 1 (13-20 Hz), beta 2 (20-30 Hz) and gamma (30-40 Hz) bands. Results: In Nold subjects, 'total coherence' of EEG across all frequency bands and electrode pairs decreased during hypercapnia, with full recovery during post-CO2. Total coherence resulted lower in pre-CO2 and post-CO2 and presented poor reactivity during CO2 inhalation in MCI patients compared with Nold subjects. Hypercapnia increased oxy-haemoglobin and decreased deoxy-haemoglobin concentrations in both groups. Furthermore, the extent of changes in these variables during CO2 challenge was correlated with the EEG coherence, as a reflection of neurovascular coupling. Conclusions: Hypercapnia induced normal frontal VMR that was detected by NIRS in both Nold and amnesic MCI groups, while it produced a reactivity of global functional coupling of resting state EEG rhythms only in the Nold group. Significance: In amnesic MCI patients, global EEG functional coupling is basically low in amplitude and does not react to hypercapnia. (C) 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
2014
resting state; amnesic mild cognitive impairment (mci); near-infrared spectroscopy (nirs); hypercapnia (co2); electroencephalography (eeg)
01 Pubblicazione su rivista::01a Articolo in rivista
Hypercapnia affects the functional coupling of resting state electroencephalographic rhythms and cerebral haemodynamics in healthy elderly subjects and in patients with amnestic mild cognitive impairment / Babiloni, Claudio; Fabrizio, Vecchio; Riccardo, Altavilla; Francesco, Tibuzzi; Lizio, Roberta; Claudia, Altamura; Paola, Palazzo; Paola, Maggio; Francesca, Ursini; Matilde, Ercolani; Andrea, Soricelli; Noce, Giuseppe; Paolo Maria, Rossini; Fabrizio, Vernieri. - In: CLINICAL NEUROPHYSIOLOGY. - ISSN 1388-2457. - 125:4(2014), pp. 685-693. [10.1016/j.clinph.2013.10.002]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/559610
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 19
social impact