A 54-year-old woman with metastatic colorectal carcinoma underwent liver radioembolization with (90)Y resin microspheres. Microsphere biodistribution was assessed 2 h after the treatment through a 20-min long (90)Y PET scan. Isodose map and lesion dose-volume histogram (DVH) were then evaluated using a MATLAB-based code. Response to therapy was assessed performing a (18)F-FDG PET 6 months after the treatment. At (90)Y PET the patient showed a well-defined horseshoe-shaped hepatic lesion with hot margins and a cold core. The lesion presented a heterogeneous DVH with a hot margin receiving an average radiation dose as high as 287 Gy and a cold area receiving an average radiation dose of 70 Gy approximately. Six months after the treatment the patient reported a complete remission of tumour areas which received a high radiation dose, while progression of metastases was observed in the area that presented scarce microsphere localization at (90)Y PET. According to our experience, the use of (90)Y PET voxel dosimetry may provide a useful tool to assess possible correlations between microsphere biodistribution and clinical outcome of the treatment. In agreement with current literature findings, an average radiation dose greater than approximately 100 Gy may be required to sterilize liver metastases

Absorbed dose to lesion and clinical outcome after liver radioembolization with 90Y microspheres: a case report of PET-based dosimetry / M., D'Arienzo; L., Filippi; P., Chiaramida; L., Chiacchiararelli; R., Cianni; R., Salvatori; Scopinaro, Francesco; O., Bagni. - In: ANNALS OF NUCLEAR MEDICINE. - ISSN 0914-7187. - STAMPA. - 27:7(2013), pp. 676-680. [10.1007/s12149-013-0726-4]

Absorbed dose to lesion and clinical outcome after liver radioembolization with 90Y microspheres: a case report of PET-based dosimetry

SCOPINARO, Francesco;
2013

Abstract

A 54-year-old woman with metastatic colorectal carcinoma underwent liver radioembolization with (90)Y resin microspheres. Microsphere biodistribution was assessed 2 h after the treatment through a 20-min long (90)Y PET scan. Isodose map and lesion dose-volume histogram (DVH) were then evaluated using a MATLAB-based code. Response to therapy was assessed performing a (18)F-FDG PET 6 months after the treatment. At (90)Y PET the patient showed a well-defined horseshoe-shaped hepatic lesion with hot margins and a cold core. The lesion presented a heterogeneous DVH with a hot margin receiving an average radiation dose as high as 287 Gy and a cold area receiving an average radiation dose of 70 Gy approximately. Six months after the treatment the patient reported a complete remission of tumour areas which received a high radiation dose, while progression of metastases was observed in the area that presented scarce microsphere localization at (90)Y PET. According to our experience, the use of (90)Y PET voxel dosimetry may provide a useful tool to assess possible correlations between microsphere biodistribution and clinical outcome of the treatment. In agreement with current literature findings, an average radiation dose greater than approximately 100 Gy may be required to sterilize liver metastases
2013
01 Pubblicazione su rivista::01a Articolo in rivista
Absorbed dose to lesion and clinical outcome after liver radioembolization with 90Y microspheres: a case report of PET-based dosimetry / M., D'Arienzo; L., Filippi; P., Chiaramida; L., Chiacchiararelli; R., Cianni; R., Salvatori; Scopinaro, Francesco; O., Bagni. - In: ANNALS OF NUCLEAR MEDICINE. - ISSN 0914-7187. - STAMPA. - 27:7(2013), pp. 676-680. [10.1007/s12149-013-0726-4]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/558764
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 27
social impact