Objective Chronic cerebrospinal venous insufficiency (CCSVI) is a recently discovered syndrome mainly due to stenoses of internal jugular (IJV) and/or azygos (AZ) veins. The present study retrospectively evaluates the feasibility and safety of endovascular treatment for CCSVI in a cohort of patients with multiple sclerosis (MS). Methods From September 2010 to October 2012, 1202 consecutive patients were admitted to undergo phlebograpy ± endovascular treatment for CCSVI. All the patients had previously been found positive at color Doppler sonography (CDS) for at least two Zamboni criteria for CCSVI and had a neurologist-confirmed diagnosis of MS. Only symptomatic MS were considered for treatment. Percutaneous transluminal angioplasty was carried out as an outpatient procedure at two different institutes. Primary procedures, regarded as the first balloon angioplasty ever performed for CCSVI, and secondary (reintervention) procedures, regarded as interventions performed after venous disease recurrence, were carried out in 86.5% (1037 of 1199) and 13.5% (162 of 1199) of patients, respectively. Procedural success and complications within 30 days were recorded. Results Phlebography followed by endovascular recanalization was carried out in 1999 patients consisting of 1219 interventions. Balloon angioplasty alone was performed in 1205 out of 1219 (98.9%) procedures, whereas additional stent placement was required in the remaining 14 procedures (1.1%) following unsuccessful attempts at AZ dilatation. No stents were ever implanted in the IJV. The feasibility rate was as high as 99.2% (1209 interventions). Major complications included one (0.1%) AZ rupture occurring during balloon dilatation and requiring blood transfusion, one (0.1%) severe bleeding in the groin requiring open surgery, two (0.2%) surgical openings of the common femoral vein to remove balloon fragments, and three (0.2%) left IJV thromboses. The overall major and minor complication rates at 30 days were 0.6% and 2.5%, respectively. Conclusions Endovascular treatment for CCSVI appears feasible and safe. However, a proper learning curve can dramatically lower the rate of adverse events. In our experience, the vast majority of complications occurred in the first 400 cases performed. Copyright © 2013 by the Society for Vascular Surgery.

Feasibility and safety of endovascular treatment for chronic cerebrospinal venous insufficiency in patients with multiple sclerosis / Tommaso, Lupattelli; Giovanni, Bellagamba; Elena, Righi; Vincenzo Di, Donna; Isac, Flaishman; Rita, Fazioli; Francesco, Garaci; Onorati, Paolo. - In: JOURNAL OF VASCULAR SURGERY. - ISSN 0741-5214. - ELETTRONICO. - 58:6(2013), pp. 1609-1618. [10.1016/j.jvs.2013.05.108]

Feasibility and safety of endovascular treatment for chronic cerebrospinal venous insufficiency in patients with multiple sclerosis

ONORATI, Paolo
2013

Abstract

Objective Chronic cerebrospinal venous insufficiency (CCSVI) is a recently discovered syndrome mainly due to stenoses of internal jugular (IJV) and/or azygos (AZ) veins. The present study retrospectively evaluates the feasibility and safety of endovascular treatment for CCSVI in a cohort of patients with multiple sclerosis (MS). Methods From September 2010 to October 2012, 1202 consecutive patients were admitted to undergo phlebograpy ± endovascular treatment for CCSVI. All the patients had previously been found positive at color Doppler sonography (CDS) for at least two Zamboni criteria for CCSVI and had a neurologist-confirmed diagnosis of MS. Only symptomatic MS were considered for treatment. Percutaneous transluminal angioplasty was carried out as an outpatient procedure at two different institutes. Primary procedures, regarded as the first balloon angioplasty ever performed for CCSVI, and secondary (reintervention) procedures, regarded as interventions performed after venous disease recurrence, were carried out in 86.5% (1037 of 1199) and 13.5% (162 of 1199) of patients, respectively. Procedural success and complications within 30 days were recorded. Results Phlebography followed by endovascular recanalization was carried out in 1999 patients consisting of 1219 interventions. Balloon angioplasty alone was performed in 1205 out of 1219 (98.9%) procedures, whereas additional stent placement was required in the remaining 14 procedures (1.1%) following unsuccessful attempts at AZ dilatation. No stents were ever implanted in the IJV. The feasibility rate was as high as 99.2% (1209 interventions). Major complications included one (0.1%) AZ rupture occurring during balloon dilatation and requiring blood transfusion, one (0.1%) severe bleeding in the groin requiring open surgery, two (0.2%) surgical openings of the common femoral vein to remove balloon fragments, and three (0.2%) left IJV thromboses. The overall major and minor complication rates at 30 days were 0.6% and 2.5%, respectively. Conclusions Endovascular treatment for CCSVI appears feasible and safe. However, a proper learning curve can dramatically lower the rate of adverse events. In our experience, the vast majority of complications occurred in the first 400 cases performed. Copyright © 2013 by the Society for Vascular Surgery.
2013
internal jugular vein (ijv); chronic cerebrospinal venous insufficiency (ccsvi); azygos (az) vein; multiple sclerosis (ms)
01 Pubblicazione su rivista::01a Articolo in rivista
Feasibility and safety of endovascular treatment for chronic cerebrospinal venous insufficiency in patients with multiple sclerosis / Tommaso, Lupattelli; Giovanni, Bellagamba; Elena, Righi; Vincenzo Di, Donna; Isac, Flaishman; Rita, Fazioli; Francesco, Garaci; Onorati, Paolo. - In: JOURNAL OF VASCULAR SURGERY. - ISSN 0741-5214. - ELETTRONICO. - 58:6(2013), pp. 1609-1618. [10.1016/j.jvs.2013.05.108]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/558352
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact