Objective. The Outcome Measures in Rheumatology (OMERACT) Filter provides a framework for the validation of outcome measures for use in rheumatology clinical research. However, imaging and biochemical measures may face additional validation challenges because of their technical nature. The Imaging and Soluble Biomarker Session at OMERACT 11 aimed to provide a guide for the iterative development of an imaging or biochemical measurement instrument so it can be used in therapeutic assessment. Methods. A hierarchical structure was proposed, reflecting 3 dimensions needed for validating an imaging or biochemical measurement instrument: outcome domain(s), study setting, and performance of the instrument. Movement along the axes in any dimension reflects increasing validation. For a given test instrument, the 3-axis structure assesses the extent to which the instrument is a validated measure for the chosen domain, whether it assesses a patient-centered or disease-centered variable, and whether its technical performance is adequate in the context of its application. Some currently used imaging and soluble biomarkers for rheumatoid arthritis, spondy-loarthritis, and knee osteoarthritis were then evaluated using the original OMERACT Filter and the newly proposed structure. Breakout groups critically reviewed the extent to which the candidate biomarkers complied with the proposed stepwise approach, as a way of examining the utility of the proposed 3-dimensional structure. Results. Although there was a broad acceptance of the value of the proposed structure in general, some areas for improvement were suggested including clarification of criteria for achieving a certain level of validation and how to deal with extension of the structure to areas beyond clinical trials. Conclusion. General support was obtained for a proposed tri-axis structure to assess validation of imaging and soluble biomarkers; nevertheless, additional work is required to better evaluate its place within the OMERACT Filter 2.0.

Updating the OMERACT Filter: Implications for Imaging and Soluble Biomarkers / M. A., D'Agostino; M., Boers; J., Kirwan; D., Van Der Heijde; M., Ostergaard; G., Schett; R. B., Landewe; W. P., Maksymowych; E., Naredo; M., Dougados; Iagnocco, Annamaria; C. O., 3rd Bingham; P. M., Brooks; D. E., Beaton; F., Gandjbakhch; L., Gossec; F., Guillemin; S. E., Hewlett; M., Kloppenburg; L., March; P. J., Mease; I., Moller; L. S., Simon; J. A., Singh; V., Strand; R. J., Wakefield; G. A., Wells; P., Tugwell; P. G., Conaghan. - In: THE JOURNAL OF RHEUMATOLOGY. - ISSN 0315-162X. - 41:5(2014), pp. 1016-1024. [10.3899/jrheum.131313]

Updating the OMERACT Filter: Implications for Imaging and Soluble Biomarkers

IAGNOCCO, Annamaria;
2014

Abstract

Objective. The Outcome Measures in Rheumatology (OMERACT) Filter provides a framework for the validation of outcome measures for use in rheumatology clinical research. However, imaging and biochemical measures may face additional validation challenges because of their technical nature. The Imaging and Soluble Biomarker Session at OMERACT 11 aimed to provide a guide for the iterative development of an imaging or biochemical measurement instrument so it can be used in therapeutic assessment. Methods. A hierarchical structure was proposed, reflecting 3 dimensions needed for validating an imaging or biochemical measurement instrument: outcome domain(s), study setting, and performance of the instrument. Movement along the axes in any dimension reflects increasing validation. For a given test instrument, the 3-axis structure assesses the extent to which the instrument is a validated measure for the chosen domain, whether it assesses a patient-centered or disease-centered variable, and whether its technical performance is adequate in the context of its application. Some currently used imaging and soluble biomarkers for rheumatoid arthritis, spondy-loarthritis, and knee osteoarthritis were then evaluated using the original OMERACT Filter and the newly proposed structure. Breakout groups critically reviewed the extent to which the candidate biomarkers complied with the proposed stepwise approach, as a way of examining the utility of the proposed 3-dimensional structure. Results. Although there was a broad acceptance of the value of the proposed structure in general, some areas for improvement were suggested including clarification of criteria for achieving a certain level of validation and how to deal with extension of the structure to areas beyond clinical trials. Conclusion. General support was obtained for a proposed tri-axis structure to assess validation of imaging and soluble biomarkers; nevertheless, additional work is required to better evaluate its place within the OMERACT Filter 2.0.
2014
biomarkers; imaging; omeract filter; outcome and process assessment; validation framework
01 Pubblicazione su rivista::01a Articolo in rivista
Updating the OMERACT Filter: Implications for Imaging and Soluble Biomarkers / M. A., D'Agostino; M., Boers; J., Kirwan; D., Van Der Heijde; M., Ostergaard; G., Schett; R. B., Landewe; W. P., Maksymowych; E., Naredo; M., Dougados; Iagnocco, Annamaria; C. O., 3rd Bingham; P. M., Brooks; D. E., Beaton; F., Gandjbakhch; L., Gossec; F., Guillemin; S. E., Hewlett; M., Kloppenburg; L., March; P. J., Mease; I., Moller; L. S., Simon; J. A., Singh; V., Strand; R. J., Wakefield; G. A., Wells; P., Tugwell; P. G., Conaghan. - In: THE JOURNAL OF RHEUMATOLOGY. - ISSN 0315-162X. - 41:5(2014), pp. 1016-1024. [10.3899/jrheum.131313]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/556978
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 14
social impact