PURPOSE: Contrast-enhanced ultrasound (CEUS) is the application of ultrasound contrast agents (UCAs) to traditional medical sonography. The development of UCAs allowed to overcome some of the limitations of conventional B-mode and Doppler ultrasound techniques and enabled the display of the parenchymal microvasculature. Purpose of this paper is to delineate the elements of a solid and science-based technique in the execution of urinary bladder CEUS. METHODS: We describe the technical execution of urinary bladder CEUS and the use of perfusion softwares to perform contrast enhancement quantitative analysis with generation of time-intensity curves from regions of interest. RESULTS: During CEUS, normal bladder wall shows a wash-in time of 13 s, a time to peak (TTP) >40 s, a signal intensity (SI) <45 % and a wash-out time >80 s; Low-grade urothelial cell carcinoma (UCC) shows a wash-in time of 13 s, a time to peak TTP >28 s, a SI <45 % and a wash-out time of 40 s; High-grade UCC shows a wash-in time of 13 s, a TTP >28 s, a SI >50 % and a wash-out time of 58 s. CONCLUSIONS: CEUS is a useful tool for an accurate characterization of bladder UCC although it has some drawbacks. To avoid misunderstandings, a widely accepted classification and a standardized terminology about the most significant parameters of this application should be adopted in the immediate future.

OBIETTIVI: l'ecografia con mezzo di contrasto (CEUS) è l'ecografia medica tradizionale con l'utilizzo di mezzi di contrasto ecografici (MDCe). Lo sviluppo di MDCe ha consentito di superare alcune delle limitazioni dell'ecografia B-mode e Doppler convenzionali ed ha consentito la visualizzazione del microcircolo parenchimale. Scopo di questo lavoro è quello di delineare gli elementi di una tecnica solida e basata sull'evidenza scientifica per l'esecuzione della CEUS della vescica urinaria. MATERIALI E METODI: Descriviamo l'esecuzione tecnica della CEUS della vescica urinaria e l'utilizzo di software di perfusione per l’esecuzione dell'analisi quantitativa dell’enhancement contrastografico con la generazione di curve intensità tempo (TIC) delle regioni di interesse (ROI). RISULTATI: Durante la CEUS, la parete della vescica normale mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >40sec., una intensità di segnale (SI) <45% e un tempo di wash-out >80 sec.; il carcinoma uroteliale (CU) di basso grado mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >28sec., un’intensità di segnale (SI) <45% e un tempo wash-out di 40 sec.; il CU di alto grado mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >28sec., un’intensità di segnale (SI) >50% e un tempo di wash-out di 58 sec. CONCLUSIONI: La CEUS è uno strumento utile per una caratterizzazione accurata del CU della vescica anche se possiede alcuni svantaggi. Al fine di evitare incomprensioni, dovrebbero essere adottate in futuro, una classificazione largamente accettata e una terminologia standardizzata sui parametri più significativi di questa applicazione.

CEUS in the study of bladder, method, administration and evaluation, a technical note / DI LEO, Nicola; Maghella, Fabrizio; Malpassini, Flavio; Iera, Jessica; Orsogna, Nicola; D'Ambrosio, Ferdinando; Drudi, Francesco Maria; Rubini, Antonello. - In: JOURNAL OF ULTRASOUND. - ISSN 1971-3495. - 17:1(2014), pp. 57-63. [10.1007/s40477-013-0032-y]

CEUS in the study of bladder, method, administration and evaluation, a technical note

DI LEO, NICOLA;MAGHELLA, FABRIZIO;MALPASSINI, FLAVIO;IERA, JESSICA;orsogna, nicola;D'AMBROSIO, Ferdinando;DRUDI, Francesco Maria;RUBINI, ANTONELLO
2014

Abstract

PURPOSE: Contrast-enhanced ultrasound (CEUS) is the application of ultrasound contrast agents (UCAs) to traditional medical sonography. The development of UCAs allowed to overcome some of the limitations of conventional B-mode and Doppler ultrasound techniques and enabled the display of the parenchymal microvasculature. Purpose of this paper is to delineate the elements of a solid and science-based technique in the execution of urinary bladder CEUS. METHODS: We describe the technical execution of urinary bladder CEUS and the use of perfusion softwares to perform contrast enhancement quantitative analysis with generation of time-intensity curves from regions of interest. RESULTS: During CEUS, normal bladder wall shows a wash-in time of 13 s, a time to peak (TTP) >40 s, a signal intensity (SI) <45 % and a wash-out time >80 s; Low-grade urothelial cell carcinoma (UCC) shows a wash-in time of 13 s, a time to peak TTP >28 s, a SI <45 % and a wash-out time of 40 s; High-grade UCC shows a wash-in time of 13 s, a TTP >28 s, a SI >50 % and a wash-out time of 58 s. CONCLUSIONS: CEUS is a useful tool for an accurate characterization of bladder UCC although it has some drawbacks. To avoid misunderstandings, a widely accepted classification and a standardized terminology about the most significant parameters of this application should be adopted in the immediate future.
2014
OBIETTIVI: l'ecografia con mezzo di contrasto (CEUS) è l'ecografia medica tradizionale con l'utilizzo di mezzi di contrasto ecografici (MDCe). Lo sviluppo di MDCe ha consentito di superare alcune delle limitazioni dell'ecografia B-mode e Doppler convenzionali ed ha consentito la visualizzazione del microcircolo parenchimale. Scopo di questo lavoro è quello di delineare gli elementi di una tecnica solida e basata sull'evidenza scientifica per l'esecuzione della CEUS della vescica urinaria. MATERIALI E METODI: Descriviamo l'esecuzione tecnica della CEUS della vescica urinaria e l'utilizzo di software di perfusione per l’esecuzione dell'analisi quantitativa dell’enhancement contrastografico con la generazione di curve intensità tempo (TIC) delle regioni di interesse (ROI). RISULTATI: Durante la CEUS, la parete della vescica normale mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >40sec., una intensità di segnale (SI) <45% e un tempo di wash-out >80 sec.; il carcinoma uroteliale (CU) di basso grado mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >28sec., un’intensità di segnale (SI) <45% e un tempo wash-out di 40 sec.; il CU di alto grado mostra un tempo di wash-in di 13 sec., un tempo di picco (TTP) >28sec., un’intensità di segnale (SI) >50% e un tempo di wash-out di 58 sec. CONCLUSIONI: La CEUS è uno strumento utile per una caratterizzazione accurata del CU della vescica anche se possiede alcuni svantaggi. Al fine di evitare incomprensioni, dovrebbero essere adottate in futuro, una classificazione largamente accettata e una terminologia standardizzata sui parametri più significativi di questa applicazione.
Bladder; CEUS; Time-intensity curves; Urothelial cell carcinoma; Radiology, Nuclear Medicine and Imaging; Internal Medicine
01 Pubblicazione su rivista::01a Articolo in rivista
CEUS in the study of bladder, method, administration and evaluation, a technical note / DI LEO, Nicola; Maghella, Fabrizio; Malpassini, Flavio; Iera, Jessica; Orsogna, Nicola; D'Ambrosio, Ferdinando; Drudi, Francesco Maria; Rubini, Antonello. - In: JOURNAL OF ULTRASOUND. - ISSN 1971-3495. - 17:1(2014), pp. 57-63. [10.1007/s40477-013-0032-y]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/555776
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact