To date, delaying cord clamping two to three minutes after birth is considered effective for newborn well-being. This time does not consider the newborn's breathing movements, which may also condition neonate well-being. To investigate the behaviour of neonatal weight loss and of some umbilical vein lab parameters, in relation to timing of newborn breathing and cord clamping. Time from birth to cord clamping and time from birth to first cry of the newborn were collected in 87 full-term healthy women. First cry is a sign of effective breathing. Birth weight loss at the first, second, and third day from birth and lab parameters were assessed in relation to: time from birth to cord clamping, time from birth to first cry, and cord clamping before or after the first cry. Partial pressure of carbon dioxide (pCO2) decreased if cord clamping was performed after first cry and increased if first cry occurred after cord clamping, independently from the time elapsed from birth to first cry (p = 0.012). Calcium (Ca(2+)) concentration decreased if cord clamping was performed after the first cry and increased if first cry of the baby after birth was delayed (p = 0.021). Each second of delay from birth to cord clamping resulted in an increase in Cl- concentration (p <0.001). Each second of delay in cord clamping resulted in a reduction in the percentage of weight loss at the first day (p = 0.024), at the second day (p = 0.007), and at the third day (p = 0.028) after birth. Neonate breathing after birth should induce umbilical vein flow from placenta to lungs, conditioning the reduction of birth weight loss after birth and umbilical lab parameters modifications.

Behaviour of lab parameters and neonatal weight loss in relation to neonatal breathing movements and cord clamping time / U., Indraccolo; R., Santafata; Palazzetti, Pier Luigi; DI IORIO, Romolo; Indraccolo, Salvatore Renato. - In: CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY. - ISSN 0390-6663. - ELETTRONICO. - 40:4(2013), pp. 557-560.

Behaviour of lab parameters and neonatal weight loss in relation to neonatal breathing movements and cord clamping time.

PALAZZETTI, Pier Luigi;DI IORIO, Romolo;INDRACCOLO, Salvatore Renato
2013

Abstract

To date, delaying cord clamping two to three minutes after birth is considered effective for newborn well-being. This time does not consider the newborn's breathing movements, which may also condition neonate well-being. To investigate the behaviour of neonatal weight loss and of some umbilical vein lab parameters, in relation to timing of newborn breathing and cord clamping. Time from birth to cord clamping and time from birth to first cry of the newborn were collected in 87 full-term healthy women. First cry is a sign of effective breathing. Birth weight loss at the first, second, and third day from birth and lab parameters were assessed in relation to: time from birth to cord clamping, time from birth to first cry, and cord clamping before or after the first cry. Partial pressure of carbon dioxide (pCO2) decreased if cord clamping was performed after first cry and increased if first cry occurred after cord clamping, independently from the time elapsed from birth to first cry (p = 0.012). Calcium (Ca(2+)) concentration decreased if cord clamping was performed after the first cry and increased if first cry of the baby after birth was delayed (p = 0.021). Each second of delay from birth to cord clamping resulted in an increase in Cl- concentration (p <0.001). Each second of delay in cord clamping resulted in a reduction in the percentage of weight loss at the first day (p = 0.024), at the second day (p = 0.007), and at the third day (p = 0.028) after birth. Neonate breathing after birth should induce umbilical vein flow from placenta to lungs, conditioning the reduction of birth weight loss after birth and umbilical lab parameters modifications.
2013
01 Pubblicazione su rivista::01a Articolo in rivista
Behaviour of lab parameters and neonatal weight loss in relation to neonatal breathing movements and cord clamping time / U., Indraccolo; R., Santafata; Palazzetti, Pier Luigi; DI IORIO, Romolo; Indraccolo, Salvatore Renato. - In: CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY. - ISSN 0390-6663. - ELETTRONICO. - 40:4(2013), pp. 557-560.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/552693
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact