The development of an endorectal PET Time Of Flight (TOF) probe prototype compatible with MRI, is going to be carried out within the INFN project TOPEM. Time resolution and depth of interaction (DOI) will allow to significantly improve the image quality, by rejecting those events coming from the surrounding tissues and correcting the parallax error. The activity described in this paper is focused on the characterization of the single pixel detector of the probe, consisting of a LYSO finger scintillator read out at both ends by means of a pair of Silicon Photomultipliers (SiPM). Energy, timing and DOI resolutions have been measured with a proper surface treatment and wrapping, finding very competitive results for DOI and timing. (C) 2012 Elsevier B.V. All rights reserved.

New developments at INFN-LNS on TOF-DOI PET based on SiPM detectors / L., Cosentino; F., Cusanno; R., De Leo; G., Di Venti; P., Finocchiaro; F., Garibaldi; F., Loddo; Meddi, Franco; P., Musico; A., Pappalardo; R., Perrino; A., Ranieri. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 702:(2013), pp. 10-12. [10.1016/j.nima.2012.08.058]

New developments at INFN-LNS on TOF-DOI PET based on SiPM detectors

MEDDI, Franco;
2013

Abstract

The development of an endorectal PET Time Of Flight (TOF) probe prototype compatible with MRI, is going to be carried out within the INFN project TOPEM. Time resolution and depth of interaction (DOI) will allow to significantly improve the image quality, by rejecting those events coming from the surrounding tissues and correcting the parallax error. The activity described in this paper is focused on the characterization of the single pixel detector of the probe, consisting of a LYSO finger scintillator read out at both ends by means of a pair of Silicon Photomultipliers (SiPM). Energy, timing and DOI resolutions have been measured with a proper surface treatment and wrapping, finding very competitive results for DOI and timing. (C) 2012 Elsevier B.V. All rights reserved.
2013
tof-doi pet; lyso; time resolution; depth of interaction; sipm
01 Pubblicazione su rivista::01a Articolo in rivista
New developments at INFN-LNS on TOF-DOI PET based on SiPM detectors / L., Cosentino; F., Cusanno; R., De Leo; G., Di Venti; P., Finocchiaro; F., Garibaldi; F., Loddo; Meddi, Franco; P., Musico; A., Pappalardo; R., Perrino; A., Ranieri. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 702:(2013), pp. 10-12. [10.1016/j.nima.2012.08.058]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/552552
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact