The paper presents the application of an ATP-EMTP Monte Carlo procedure for backflashover rate (BFOR) evaluations to HV overhead lines (OHL), equipped with three different types of spatially extended and/or geometrically involved tower grounding systems. The ATP-EMTP circuit model of the OHL includes detailed line insulation and lightning representation; grounding systems are simulated by a new and simplified model which reproduces the effects of propagation along the ground conductors and soil ionization phenomena. The statistical variables include lightning stroke parameters (polarity, peak current, front and tail times), lightning location, as well as line insulation withstand and phase angle of the supply voltage. An external software engine generates all the required statistically-oriented ATP-EMTP input data, sequentially launches and manages ATP simulations and finally post-processes the results. A good performance in terms of convergence and computation times is evidenced. Resu

The paper presents the application of an ATP-EMTP Monte Carlo procedure for backflashover rate (BFOR) evaluations to HV overhead lines (OHL), equipped with three different types of spatially extended and/or geometrically involved tower grounding systems. The ATP-EMTP circuit model of the OHL includes detailed line insulation and lightning representation; grounding systems are simulated by a new and simplified model which reproduces the effects of propagation along the ground conductors and soil ionization phenomena. The statistical variables include lightning stroke parameters (polarity, peak current, front and tail times), lightning location, as well as line insulation withstand and phase angle of the supply voltage. An external software engine generates all the required statistically-oriented ATP-EMTP input data, sequentially launches and manages ATP simulations and finally post-processes the results. A good performance in terms of convergence and computation times is evidenced. Results are compared to those yielded by both the simplified and ‘complete’ CIGRE methods for backflashover rate calculations, showing the applicability of the proposed procedure to line configurations characterized by complex tower grounding arrangements.

An ATP-EMTP Monte Carlo procedure for backflashover rate evaluation: A comparison with the CIGRE method / Gatta, Fabio Massimo; Geri, Alberto; Lauria, Stefano; Maccioni, Marco; A., Santarpia. - In: ELECTRIC POWER SYSTEMS RESEARCH. - ISSN 0378-7796. - STAMPA. - 113:(2014), pp. 134-140. [10.1016/j.epsr.2014.02.031]

An ATP-EMTP Monte Carlo procedure for backflashover rate evaluation: A comparison with the CIGRE method

GATTA, Fabio Massimo;GERI, Alberto;LAURIA, Stefano;MACCIONI, Marco;
2014

Abstract

The paper presents the application of an ATP-EMTP Monte Carlo procedure for backflashover rate (BFOR) evaluations to HV overhead lines (OHL), equipped with three different types of spatially extended and/or geometrically involved tower grounding systems. The ATP-EMTP circuit model of the OHL includes detailed line insulation and lightning representation; grounding systems are simulated by a new and simplified model which reproduces the effects of propagation along the ground conductors and soil ionization phenomena. The statistical variables include lightning stroke parameters (polarity, peak current, front and tail times), lightning location, as well as line insulation withstand and phase angle of the supply voltage. An external software engine generates all the required statistically-oriented ATP-EMTP input data, sequentially launches and manages ATP simulations and finally post-processes the results. A good performance in terms of convergence and computation times is evidenced. Resu
2014
The paper presents the application of an ATP-EMTP Monte Carlo procedure for backflashover rate (BFOR) evaluations to HV overhead lines (OHL), equipped with three different types of spatially extended and/or geometrically involved tower grounding systems. The ATP-EMTP circuit model of the OHL includes detailed line insulation and lightning representation; grounding systems are simulated by a new and simplified model which reproduces the effects of propagation along the ground conductors and soil ionization phenomena. The statistical variables include lightning stroke parameters (polarity, peak current, front and tail times), lightning location, as well as line insulation withstand and phase angle of the supply voltage. An external software engine generates all the required statistically-oriented ATP-EMTP input data, sequentially launches and manages ATP simulations and finally post-processes the results. A good performance in terms of convergence and computation times is evidenced. Results are compared to those yielded by both the simplified and ‘complete’ CIGRE methods for backflashover rate calculations, showing the applicability of the proposed procedure to line configurations characterized by complex tower grounding arrangements.
Backflashover rate; HV overhead line; Grounding system; ATP-EMTP; Monte Carlo
01 Pubblicazione su rivista::01a Articolo in rivista
An ATP-EMTP Monte Carlo procedure for backflashover rate evaluation: A comparison with the CIGRE method / Gatta, Fabio Massimo; Geri, Alberto; Lauria, Stefano; Maccioni, Marco; A., Santarpia. - In: ELECTRIC POWER SYSTEMS RESEARCH. - ISSN 0378-7796. - STAMPA. - 113:(2014), pp. 134-140. [10.1016/j.epsr.2014.02.031]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/551985
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 25
social impact