Purpose: To compare the success in repair of dural tears (DTs) using two different surgical sealants in non-instrumented lumbar spinal surgery and evaluate the incidence of associated short- and long-term complications. Methods: Twenty-three patients undergoing non-instrumented spinal surgery with intraoperative DTs were included both retrospectively and prospectively in this study. External signs of CSF leakage, neurological deficits, and infection-related complications were investigated postoperatively. The persistence of low-back pain was also evaluated and postoperative MRI was performed in all patients. DTs were repaired intraoperatively using suture with or without a dural patch. Eleven patients received an application of fibrin glue (Tissucol®; Baxter, Inc., IL, USA) and 12 patients received an application of bovine serum albumin glutaraldehyde surgical adhesive (BioGlue® Surgical Adhesive; CryoLife, GA, USA). These patients were followed up at 3 months and 1 year postoperatively. Results: Successful intraoperative DT repair was obtained in all cases. Three patients in the Tissucol group presented with CSF leakage in the early postoperative period. There were no complications observed in the patients treated with BioGlue. At 3-month follow-up, no incidences of neurological or infection-related complications were observed in either group. There was no statistically significant difference in VAS between the two treatment groups. Conclusions: Intraoperative DTs can be easily repaired by many effective techniques. However, in our experience, the use of BioGlue is an effective adjunct to immediate dural repair, being comparable in terms of efficacy and safety to the use of fibrin glue, potentially decreasing the incidence of associated short- and long-term complications. © 2014 The Author(s).

The use of surgical sealants in the repair of dural tears during non-instrumented spinal surgery / Miscusi, Massimo; Polli, FILIPPO MARIA; Forcato, Stefano; Maria Antoaneta Coman, ; Ricciardi, Luca; Ramieri, Alessandro; Raco, Antonino. - In: EUROPEAN SPINE JOURNAL. - ISSN 0940-6719. - STAMPA. - 23:8(2014), pp. 1761-1766. [10.1007/s00586-013-3138-1]

The use of surgical sealants in the repair of dural tears during non-instrumented spinal surgery

MISCUSI, MASSIMO;POLLI, FILIPPO MARIA;FORCATO, STEFANO;Luca Ricciardi;RAMIERI, ALESSANDRO;RACO, Antonino
2014

Abstract

Purpose: To compare the success in repair of dural tears (DTs) using two different surgical sealants in non-instrumented lumbar spinal surgery and evaluate the incidence of associated short- and long-term complications. Methods: Twenty-three patients undergoing non-instrumented spinal surgery with intraoperative DTs were included both retrospectively and prospectively in this study. External signs of CSF leakage, neurological deficits, and infection-related complications were investigated postoperatively. The persistence of low-back pain was also evaluated and postoperative MRI was performed in all patients. DTs were repaired intraoperatively using suture with or without a dural patch. Eleven patients received an application of fibrin glue (Tissucol®; Baxter, Inc., IL, USA) and 12 patients received an application of bovine serum albumin glutaraldehyde surgical adhesive (BioGlue® Surgical Adhesive; CryoLife, GA, USA). These patients were followed up at 3 months and 1 year postoperatively. Results: Successful intraoperative DT repair was obtained in all cases. Three patients in the Tissucol group presented with CSF leakage in the early postoperative period. There were no complications observed in the patients treated with BioGlue. At 3-month follow-up, no incidences of neurological or infection-related complications were observed in either group. There was no statistically significant difference in VAS between the two treatment groups. Conclusions: Intraoperative DTs can be easily repaired by many effective techniques. However, in our experience, the use of BioGlue is an effective adjunct to immediate dural repair, being comparable in terms of efficacy and safety to the use of fibrin glue, potentially decreasing the incidence of associated short- and long-term complications. © 2014 The Author(s).
2014
bioglue; fibrin glue; duraplasty; dural tear; incidental durotomy; csf leakage
01 Pubblicazione su rivista::01a Articolo in rivista
The use of surgical sealants in the repair of dural tears during non-instrumented spinal surgery / Miscusi, Massimo; Polli, FILIPPO MARIA; Forcato, Stefano; Maria Antoaneta Coman, ; Ricciardi, Luca; Ramieri, Alessandro; Raco, Antonino. - In: EUROPEAN SPINE JOURNAL. - ISSN 0940-6719. - STAMPA. - 23:8(2014), pp. 1761-1766. [10.1007/s00586-013-3138-1]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/547509
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 20
social impact