The counterintuitive behaviours associated with Smith-Herrmann’s columns under follower force and on elastic foundation, as well as the Bernoulli-Euler pipe conveying fluid on a partial elastic foundation, are re-examined. It is shown that treating the pipe as a Timoshenko beam removes, albeit not always, the paradoxical patterns of stability loss.
A contribution to clarify paradoxes associated with so-called follower forces / Ruta, G., Elishakoff, I.. - STAMPA. - (2003), pp. 179-188. (XVI Congresso AIMETA Ferrara ).
A contribution to clarify paradoxes associated with so-called follower forces
RUTA, Giuseppe
Primo
Membro del Collaboration Group
;
2003
Abstract
The counterintuitive behaviours associated with Smith-Herrmann’s columns under follower force and on elastic foundation, as well as the Bernoulli-Euler pipe conveying fluid on a partial elastic foundation, are re-examined. It is shown that treating the pipe as a Timoshenko beam removes, albeit not always, the paradoxical patterns of stability loss.File allegati a questo prodotto
| File | Dimensione | Formato | |
|---|---|---|---|
|
Ruta_Contribution_2003.pdf
solo gestori archivio
Note: "articolo principale"
Tipologia:
Documento in Pre-print (manoscritto inviato all'editore, precedente alla peer review)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
231.94 kB
Formato
Adobe PDF
|
231.94 kB | Adobe PDF | Contatta l'autore |