OBJECTIVES:Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). MATERIALS AND METHODS: Data were prospectively collected on a 6-month period and included 3376 patients (47.2±19 years; range 1-92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. RESULTS: Exams were performed with 1.5T scanners in 96% of cases followed by 3T (3%) and 1T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases

Objectives Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1-92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile. © 2013 Elsevier Ireland Ltd.

Italian registry of cardiac magnetic resonance / Francone, Marco; Ernesto Di, Cesare; Filippo, Cademartiri; Gianluca, Pontone; Luigi, Lovato; Gildo, Matta; Francesco, Secchi; Erica, Maffei; Silvia, Pradella; Carbone, Iacopo; Riccardo, Marano; Lorenzo, Bacigalupo; Elisabetta, Chiodi; Rocco, Donato; Stefano, Sbarbati; Francesco De, Cobelli; P., Cmr Italian Registry Group Di Renzi. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 83:1(2013), pp. e15-e22. [10.1016/j.ejrad.2013.10.006]

Italian registry of cardiac magnetic resonance

FRANCONE, MARCO;CARBONE, IACOPO;
2013

Abstract

OBJECTIVES:Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). MATERIALS AND METHODS: Data were prospectively collected on a 6-month period and included 3376 patients (47.2±19 years; range 1-92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. RESULTS: Exams were performed with 1.5T scanners in 96% of cases followed by 3T (3%) and 1T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases
2013
Objectives Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1-92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile. © 2013 Elsevier Ireland Ltd.
safety profile; acquisition protocols; patient's management; clinical indications; cmr-registry
01 Pubblicazione su rivista::01a Articolo in rivista
Italian registry of cardiac magnetic resonance / Francone, Marco; Ernesto Di, Cesare; Filippo, Cademartiri; Gianluca, Pontone; Luigi, Lovato; Gildo, Matta; Francesco, Secchi; Erica, Maffei; Silvia, Pradella; Carbone, Iacopo; Riccardo, Marano; Lorenzo, Bacigalupo; Elisabetta, Chiodi; Rocco, Donato; Stefano, Sbarbati; Francesco De, Cobelli; P., Cmr Italian Registry Group Di Renzi. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 83:1(2013), pp. e15-e22. [10.1016/j.ejrad.2013.10.006]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/534073
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact