Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of the heat and light signals produced by particles interacting in scintillating bolometers, as proposed by the LUCIFER experiment. In this framework, the choice of the light detector and the optimization of its working conditions play a crucial role. In this paper, we report a study of the performances of a Germanium bolometric light detector in terms of signal amplitude, energy resolution and signal time development. The impact of various operational parameters on the detector performances is discussed.

Characterization of bolometric light detectors for rare event searches / J. W., Beeman; Bellini, Fabio; Casali, Nicola; Cardani, Laura; Dafinei, Ioan; S., Di Domizio; S., Di Domizio; Ferroni, Fernando; L., Gironi; S., Nagorny; Orio, Filippo; L., Pattavina; G., Pessina; Piperno, Gabriele; S., Pirro; E., Previtali; C., Rusconi; C., Tomei; Vignati, Marco. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:7(2013), pp. P07021-P07021. [10.1088/1748-0221/8/07/p07021]

Characterization of bolometric light detectors for rare event searches

BELLINI, Fabio;CASALI, NICOLA;CARDANI, LAURA;DAFINEI, Ioan;FERRONI, Fernando;ORIO, FILIPPO;PIPERNO, GABRIELE;VIGNATI, Marco
2013

Abstract

Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of the heat and light signals produced by particles interacting in scintillating bolometers, as proposed by the LUCIFER experiment. In this framework, the choice of the light detector and the optimization of its working conditions play a crucial role. In this paper, we report a study of the performances of a Germanium bolometric light detector in terms of signal amplitude, energy resolution and signal time development. The impact of various operational parameters on the detector performances is discussed.
2013
hgi etc); gamma detectors (scintillators; x-ray detectors; hpg; solid state detectors; czt; cryogenic detectors
01 Pubblicazione su rivista::01a Articolo in rivista
Characterization of bolometric light detectors for rare event searches / J. W., Beeman; Bellini, Fabio; Casali, Nicola; Cardani, Laura; Dafinei, Ioan; S., Di Domizio; S., Di Domizio; Ferroni, Fernando; L., Gironi; S., Nagorny; Orio, Filippo; L., Pattavina; G., Pessina; Piperno, Gabriele; S., Pirro; E., Previtali; C., Rusconi; C., Tomei; Vignati, Marco. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:7(2013), pp. P07021-P07021. [10.1088/1748-0221/8/07/p07021]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/527750
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 61
social impact