A new and sensitive liquid chromatography/electrospray-tandem mass spectrometric (LC/ESI-MS/MS) method for the determination of 12 perfluorinated compounds (PFCs) in cow milk is described. Milk samples were extracted with acetone and cleaned-up by a graphitized carbon black solid-phase extraction cartridge, optimizing the entire procedure by using a screening experimental design. LC/ESI-MS/MS was performed in negative ion mode using multiple reaction monitoring mode. The performance of the method was evaluated under the optimized conditions in terms of matrix effects, range of linearity, accuracy, and repeatability. For all compounds, linearity in matrix was observed in the range LOQ-10 mu g L-1, and coefficients of determination R-2 ranged from 0.9982 to 0.9999. The analytical recoveries, relative to the isotopic internal standard, measured at 10 and 50 ng L-1 were in the range of 91-105%, with relative standard deviations below 6% and method detection limit, based on the blank value +3 times the standard deviation of the blank, ranged from 0.5 to 3 ng L-1. The final method developed was used to determine the concentration of PFCs in 15 retail milk samples. None of these compounds were detected in cow milk analyzed samples. (C) 2013 Elsevier B.V. All rights reserved.

High performance liquid chromatography tandem mass spectrometry determination of perfluorinated acids in cow milk / Capriotti, ANNA LAURA; Cavaliere, Chiara; Alberto, Cavazzini; Foglia, Patrizia; Lagana', Aldo; Piovesana, Susy; Samperi, Roberto. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1319:(2013), pp. 72-79. [10.1016/j.chroma.2013.10.029]

High performance liquid chromatography tandem mass spectrometry determination of perfluorinated acids in cow milk

CAPRIOTTI, ANNA LAURA;CAVALIERE, CHIARA;FOGLIA, Patrizia;LAGANA', Aldo;PIOVESANA, SUSY;SAMPERI, Roberto
2013

Abstract

A new and sensitive liquid chromatography/electrospray-tandem mass spectrometric (LC/ESI-MS/MS) method for the determination of 12 perfluorinated compounds (PFCs) in cow milk is described. Milk samples were extracted with acetone and cleaned-up by a graphitized carbon black solid-phase extraction cartridge, optimizing the entire procedure by using a screening experimental design. LC/ESI-MS/MS was performed in negative ion mode using multiple reaction monitoring mode. The performance of the method was evaluated under the optimized conditions in terms of matrix effects, range of linearity, accuracy, and repeatability. For all compounds, linearity in matrix was observed in the range LOQ-10 mu g L-1, and coefficients of determination R-2 ranged from 0.9982 to 0.9999. The analytical recoveries, relative to the isotopic internal standard, measured at 10 and 50 ng L-1 were in the range of 91-105%, with relative standard deviations below 6% and method detection limit, based on the blank value +3 times the standard deviation of the blank, ranged from 0.5 to 3 ng L-1. The final method developed was used to determine the concentration of PFCs in 15 retail milk samples. None of these compounds were detected in cow milk analyzed samples. (C) 2013 Elsevier B.V. All rights reserved.
2013
graphitized carbon black; experimental design; lc-ms; milk; perfluoro acids; solid phase extraction (spe)
01 Pubblicazione su rivista::01a Articolo in rivista
High performance liquid chromatography tandem mass spectrometry determination of perfluorinated acids in cow milk / Capriotti, ANNA LAURA; Cavaliere, Chiara; Alberto, Cavazzini; Foglia, Patrizia; Lagana', Aldo; Piovesana, Susy; Samperi, Roberto. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1319:(2013), pp. 72-79. [10.1016/j.chroma.2013.10.029]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/526364
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 26
social impact