Drug-coated balloons are a new tool for the treatment of patients with coronary artery disease. The main feature of this technology is a rapid and homogeneous transfer of an antiproliferative drug (paclitaxel) to the vessel wall just at the time of balloon inflation, when neointimal proliferation, in response to angioplasty, is the highest. Moreover, drug-coated balloons share adjunctive advantages over stents: the absence of permanent scaffold and polymer, the respect of the original coronary anatomy, and limited inflammatory stimuli, thereby allowing for short-term dual antiplatelet therapy. At present, a variety of devices are available in the market, with limited scientific data for the vast majority of them. Thus, the Italian Society of Interventional Cardiology (SICI-GISE) decided to coordinate the efforts of a group of renowned experts in this field, in order to produce a position paper on the correct use of drug-coated balloons in all settings of coronary artery disease, giving a class of indication to each one, based on clinical evidence. This position paper represents a quick reference for operators, investigators and manufacturers to promote the understanding and the correct use of the drug-coated balloon technology in everyday clinical practice.

[SICI-GISE position paper on drug-coated balloon use in the coronary district] / B., Cortese; G. A., Sgueglia; S., Berti; BIONDI ZOCCAI, Giuseppe; A., Colombo; U., Limbruno; F., Bedogni; A., Cremonesi. - In: GIORNALE ITALIANO DI CARDIOLOGIA. - ISSN 1827-6806. - STAMPA. - 14:10(2013). [10.1714/1335.14836]

[SICI-GISE position paper on drug-coated balloon use in the coronary district].

BIONDI ZOCCAI, GIUSEPPE;
2013

Abstract

Drug-coated balloons are a new tool for the treatment of patients with coronary artery disease. The main feature of this technology is a rapid and homogeneous transfer of an antiproliferative drug (paclitaxel) to the vessel wall just at the time of balloon inflation, when neointimal proliferation, in response to angioplasty, is the highest. Moreover, drug-coated balloons share adjunctive advantages over stents: the absence of permanent scaffold and polymer, the respect of the original coronary anatomy, and limited inflammatory stimuli, thereby allowing for short-term dual antiplatelet therapy. At present, a variety of devices are available in the market, with limited scientific data for the vast majority of them. Thus, the Italian Society of Interventional Cardiology (SICI-GISE) decided to coordinate the efforts of a group of renowned experts in this field, in order to produce a position paper on the correct use of drug-coated balloons in all settings of coronary artery disease, giving a class of indication to each one, based on clinical evidence. This position paper represents a quick reference for operators, investigators and manufacturers to promote the understanding and the correct use of the drug-coated balloon technology in everyday clinical practice.
2013
01 Pubblicazione su rivista::01a Articolo in rivista
[SICI-GISE position paper on drug-coated balloon use in the coronary district] / B., Cortese; G. A., Sgueglia; S., Berti; BIONDI ZOCCAI, Giuseppe; A., Colombo; U., Limbruno; F., Bedogni; A., Cremonesi. - In: GIORNALE ITALIANO DI CARDIOLOGIA. - ISSN 1827-6806. - STAMPA. - 14:10(2013). [10.1714/1335.14836]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/526037
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact