The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test. 24 Hyflex® size 40 taper.04 nickel titanium instruments were randomly divided in two groups (n=12 each), and submitted to a cyclic fatigue test. The first group (CR group) were used with a continuous rotation, while the second one (RCP group) with a reciprocating motion. The cyclic fatigue tests were performed by using a stainless steel block containing an artificial canal shaped with a 135° angle. All instruments were rotated or reciprocated until fracture occurred. The time to fracture was recorded visually with a 1/100 second chronometer. Data were recorded and statistically analysed. Results indicated that instruments used with a reciprocating motion showed a significant increase in the meantime to failure when compared to those used in continuous rotation. The null hypothesis was rejected. Results of the present study showed that reciprocating motion extended resistance to cyclic fatigue of the tested nickel titanium instruments, when compared to continuous rotation.

Influence of file motion on cyclic fatigue of new nickel titanium instruments / A. g., Rubini; G., Sannino; G., Pongione; Testarelli, Luca; D., Al Sudani; J., Jantarat; DE LUCA, Massimo; Gambarini, Gianluca. - In: ANNALI DI STOMATOLOGIA. - ISSN 1971-1441. - 4:1(2013), pp. 149-151. [10.11138/ads.0149]

Influence of file motion on cyclic fatigue of new nickel titanium instruments.

TESTARELLI, Luca;DE LUCA, MASSIMO;GAMBARINI, Gianluca
2013

Abstract

The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test. 24 Hyflex® size 40 taper.04 nickel titanium instruments were randomly divided in two groups (n=12 each), and submitted to a cyclic fatigue test. The first group (CR group) were used with a continuous rotation, while the second one (RCP group) with a reciprocating motion. The cyclic fatigue tests were performed by using a stainless steel block containing an artificial canal shaped with a 135° angle. All instruments were rotated or reciprocated until fracture occurred. The time to fracture was recorded visually with a 1/100 second chronometer. Data were recorded and statistically analysed. Results indicated that instruments used with a reciprocating motion showed a significant increase in the meantime to failure when compared to those used in continuous rotation. The null hypothesis was rejected. Results of the present study showed that reciprocating motion extended resistance to cyclic fatigue of the tested nickel titanium instruments, when compared to continuous rotation.
2013
01 Pubblicazione su rivista::01a Articolo in rivista
Influence of file motion on cyclic fatigue of new nickel titanium instruments / A. g., Rubini; G., Sannino; G., Pongione; Testarelli, Luca; D., Al Sudani; J., Jantarat; DE LUCA, Massimo; Gambarini, Gianluca. - In: ANNALI DI STOMATOLOGIA. - ISSN 1971-1441. - 4:1(2013), pp. 149-151. [10.11138/ads.0149]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/525262
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact