A liquid chromatography-tandem mass spectrometry analytical procedure has been developed for the detection and quantitative determination of underivatized amino acids at low concentrations in a Standard Reference Material - urban dust. In order to minimize interferences of other compounds, an accelerated solvent extraction followed by a solid phase extraction on two different cartridges was applied prior to LC-MS-MS. Fourteen amino acids were separated by high resolution liquid chromatography, detected and quantified by multiple reaction monitoring on a triple quadrupole. The proposed methodology has been applied for the first time on Standard Reference Material 1649a (urban dust) from the National Institute of Standards and Technology, that does not report certification values for these compounds. This methodology avoids the derivatization step and allows the amino acid quantification in a complex matrix, such as that of atmospheric particulate matter, and represent a good method suitable to analyze this class of compounds in atmospheric aerosol. The selected strategy demonstrated to be fit-for-purpose, by applying it to a real atmospheric sample with the aim to verify the efficacy of the study and to provide information about the organic matter content. © 2013 Elsevier B.V.

Development of a method for the analysis of underivatized amino acids by liquid chromatography/tandem mass spectrometry: Application on Standard Reference Material 1649a (urban dust) / Buiarelli, Francesca; Valentina, Gallo; DI FILIPPO, Patrizia; Donatella, Pomata; Carmela, Riccardi. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 115:(2013), pp. 966-972. [10.1016/j.talanta.2013.07.009]

Development of a method for the analysis of underivatized amino acids by liquid chromatography/tandem mass spectrometry: Application on Standard Reference Material 1649a (urban dust)

BUIARELLI, Francesca;DI FILIPPO, PATRIZIA;
2013

Abstract

A liquid chromatography-tandem mass spectrometry analytical procedure has been developed for the detection and quantitative determination of underivatized amino acids at low concentrations in a Standard Reference Material - urban dust. In order to minimize interferences of other compounds, an accelerated solvent extraction followed by a solid phase extraction on two different cartridges was applied prior to LC-MS-MS. Fourteen amino acids were separated by high resolution liquid chromatography, detected and quantified by multiple reaction monitoring on a triple quadrupole. The proposed methodology has been applied for the first time on Standard Reference Material 1649a (urban dust) from the National Institute of Standards and Technology, that does not report certification values for these compounds. This methodology avoids the derivatization step and allows the amino acid quantification in a complex matrix, such as that of atmospheric particulate matter, and represent a good method suitable to analyze this class of compounds in atmospheric aerosol. The selected strategy demonstrated to be fit-for-purpose, by applying it to a real atmospheric sample with the aim to verify the efficacy of the study and to provide information about the organic matter content. © 2013 Elsevier B.V.
2013
atmosperic amino acids; atmospheric amino acids; liquid chromatography-tandem mass spectrometry; method development; standard reference material 1649a; underivatized amino acid detection
01 Pubblicazione su rivista::01a Articolo in rivista
Development of a method for the analysis of underivatized amino acids by liquid chromatography/tandem mass spectrometry: Application on Standard Reference Material 1649a (urban dust) / Buiarelli, Francesca; Valentina, Gallo; DI FILIPPO, Patrizia; Donatella, Pomata; Carmela, Riccardi. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 115:(2013), pp. 966-972. [10.1016/j.talanta.2013.07.009]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/524548
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 24
social impact