Objectives: To evaluate if Diffusion Tensor Imaging technique (DTI) can improve the visualization of periprostatic nerve fibers describing the location and distribution of entire neurovascular plexus around the prostate in patients who are candidates for prostatectomy. Materials and methods: Magnetic Resonance Imaging (MRI), including a 2D T2-weighted FSE sequence in 3 planes, 3D T2-weighted and DTI using 16 gradient directions and b = 0 and 1000, was performed on 36 patients. Three out of 36 patients were excluded from the analysis due to poor image quality (blurring N = 2, artifact N = 1). The study was approved by local ethics committee and all patients gave an informed consent. Images were evaluated by two radiologists with different experience in MRI. DTI images were analyzed qualitatively using dedicated software. Also 2D and 3D T2 images were independently considered. Results: 3D-DTI allowed description of the entire plexus of the periprostatic nerve fibers in all directions, while 2D and 3D T2 morphological sequences depicted part of the fibers, in a plane by plane analysis of fiber courses. DTI demonstrated in all patients the dispersion of nerve fibers around the prostate on both sides including the significant percentage present in the anterior and anterolateral sectors. Conclusions: DTI offers optimal representation of the widely distributed periprostatic plexus. If validated, it may help guide nerve-sparing radical prostatectomy. (C) 2013 Elsevier Ireland Ltd. All rights reserved.

In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR Diffusion Tensor Imaging / Panebianco, Valeria; Flavio, Barchetti; Sciarra, Alessandro; Andrea, Marcantonio; Zini, Chiara; Salciccia, Stefano; Federico, Collettini; Gentile, Vincenzo; Bernard, Hamm; Catalano, Carlo. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - STAMPA. - 82:10(2013), pp. 1677-1682. [10.1016/j.ejrad.2013.05.013]

In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR Diffusion Tensor Imaging

PANEBIANCO, VALERIA;SCIARRA, Alessandro;ZINI, CHIARA;SALCICCIA, STEFANO;GENTILE, Vincenzo;CATALANO, Carlo
2013

Abstract

Objectives: To evaluate if Diffusion Tensor Imaging technique (DTI) can improve the visualization of periprostatic nerve fibers describing the location and distribution of entire neurovascular plexus around the prostate in patients who are candidates for prostatectomy. Materials and methods: Magnetic Resonance Imaging (MRI), including a 2D T2-weighted FSE sequence in 3 planes, 3D T2-weighted and DTI using 16 gradient directions and b = 0 and 1000, was performed on 36 patients. Three out of 36 patients were excluded from the analysis due to poor image quality (blurring N = 2, artifact N = 1). The study was approved by local ethics committee and all patients gave an informed consent. Images were evaluated by two radiologists with different experience in MRI. DTI images were analyzed qualitatively using dedicated software. Also 2D and 3D T2 images were independently considered. Results: 3D-DTI allowed description of the entire plexus of the periprostatic nerve fibers in all directions, while 2D and 3D T2 morphological sequences depicted part of the fibers, in a plane by plane analysis of fiber courses. DTI demonstrated in all patients the dispersion of nerve fibers around the prostate on both sides including the significant percentage present in the anterior and anterolateral sectors. Conclusions: DTI offers optimal representation of the widely distributed periprostatic plexus. If validated, it may help guide nerve-sparing radical prostatectomy. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
2013
erectile disfunction; resonance; prostatectomy; diffusion mri; prostate cancer; imaging; diffusion tensor imaging
01 Pubblicazione su rivista::01a Articolo in rivista
In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR Diffusion Tensor Imaging / Panebianco, Valeria; Flavio, Barchetti; Sciarra, Alessandro; Andrea, Marcantonio; Zini, Chiara; Salciccia, Stefano; Federico, Collettini; Gentile, Vincenzo; Bernard, Hamm; Catalano, Carlo. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - STAMPA. - 82:10(2013), pp. 1677-1682. [10.1016/j.ejrad.2013.05.013]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/519385
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 32
social impact