The present paper addresses the analysis of the ambient vibrations of the Basilica of Maxentius in Rome. This monument, in the city centre and close to busy roads, was the largest vaulted structure in the Roman Empire. Today, only one aisle of the structure remains, su®ering from a complex crack scenario. The ambient vibration response is used to investigate traffic induced vibration and compare this to values that could be a potential cause of structural damage according to international standards. Using output-only methods, natural frequencies and mode shapes are obtained from the response, allowing comparison with predictions made with a finite element model. Notwithstanding simplifications regarding material behaviorand crack pattern in the finite element model, an agreement between numerical and experimental results is reached once selected mechanical parameters are adjusted. A knowledge of modal characteristics and the availability of an updated model may be a first step of a structural monitoring program thatcould reveal any decay over time in the structural integrity of the monument.
Vibration Assessment and Structural Monitoring of the Basilica of Maxentius in Rome / Pau, A.; Vestroni, F.. - In: MECHANICAL SYSTEMS AND SIGNAL PROCESSING. - ISSN 0888-3270. - STAMPA. - 41:1-2(2013), pp. 454-466. [10.1016/j.ymssp.2013.05.009]
Vibration Assessment and Structural Monitoring of the Basilica of Maxentius in Rome
A. Pau;F. Vestroni
2013
Abstract
The present paper addresses the analysis of the ambient vibrations of the Basilica of Maxentius in Rome. This monument, in the city centre and close to busy roads, was the largest vaulted structure in the Roman Empire. Today, only one aisle of the structure remains, su®ering from a complex crack scenario. The ambient vibration response is used to investigate traffic induced vibration and compare this to values that could be a potential cause of structural damage according to international standards. Using output-only methods, natural frequencies and mode shapes are obtained from the response, allowing comparison with predictions made with a finite element model. Notwithstanding simplifications regarding material behaviorand crack pattern in the finite element model, an agreement between numerical and experimental results is reached once selected mechanical parameters are adjusted. A knowledge of modal characteristics and the availability of an updated model may be a first step of a structural monitoring program thatcould reveal any decay over time in the structural integrity of the monument.File | Dimensione | Formato | |
---|---|---|---|
Pau_Vibration_2013.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.81 MB
Formato
Adobe PDF
|
1.81 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.