ISPRA, the Italian nuclear safety regulatory body, has started a measurement campaign for validating the performances of in situ gamma-ray spectrometry based on BEGe detectors and ISOCS software. The goal of the validation program is to verify if the mathematical algorithms used by Canberra to account for collimation effects of HpGe detectors continue to work well also for BEGe detectors. This has required the development of a calibration methodology, based on MCNPX code, which, by avoiding any mathematical algorithm utilization, is purely stochastic.Experimental results obtained by such a new procedure, were generally found to be 5% of the reference values. While, in the case of gamma-ray energies greater than 400 keV and small angles collimation, results given by ISOCS software produced larger deviations, around 20%. This work presents a detailed description of the simulation procedure and of the first experimental results: (C) 2013 Elsevier B.V. All rights reserved.

Development of a stochastic detection efficiency calibration procedure for studying collimation effects on a broad energy germanium detector / Massimo, Altavilla; Remetti, Romolo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 712:(2013), pp. 157-161. [10.1016/j.nima.2013.02.019]

Development of a stochastic detection efficiency calibration procedure for studying collimation effects on a broad energy germanium detector

REMETTI, Romolo
2013

Abstract

ISPRA, the Italian nuclear safety regulatory body, has started a measurement campaign for validating the performances of in situ gamma-ray spectrometry based on BEGe detectors and ISOCS software. The goal of the validation program is to verify if the mathematical algorithms used by Canberra to account for collimation effects of HpGe detectors continue to work well also for BEGe detectors. This has required the development of a calibration methodology, based on MCNPX code, which, by avoiding any mathematical algorithm utilization, is purely stochastic.Experimental results obtained by such a new procedure, were generally found to be 5% of the reference values. While, in the case of gamma-ray energies greater than 400 keV and small angles collimation, results given by ISOCS software produced larger deviations, around 20%. This work presents a detailed description of the simulation procedure and of the first experimental results: (C) 2013 Elsevier B.V. All rights reserved.
2013
isocs; mcnpx; gamma-ray spectrometry; collimator algorithms; bege; gamma spectrometry; broad energy germanium detector
01 Pubblicazione su rivista::01a Articolo in rivista
Development of a stochastic detection efficiency calibration procedure for studying collimation effects on a broad energy germanium detector / Massimo, Altavilla; Remetti, Romolo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 712:(2013), pp. 157-161. [10.1016/j.nima.2013.02.019]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/513250
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact