Background: Measurement of thyroglobulin (Tg) protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C) has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN) metastasis from well-differentiated thyroid cancer (TC). In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp), Tg mRNA (FNAB-Tgm) and calcitonin (CT) mRNA (FNAB-CTm) in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods. In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC) in 26 CLN, metastatic medullary TC (MTC) in 3 CLN, metastatic anaplastic TC (ATC) in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results: The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions: We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters. © 2013 Baldini et al.; licensee BioMed Central Ltd.

Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology? / Baldini, Enke; Sorrenti, Salvatore; DI GIOIA, Cira Rosaria Tiziana; DE VITO, Corrado; Alessandro, Antonelli; Gnessi, Lucio; Carbotta, Giovanni; Eleonora, D'Armiento; Paolo, Miccoli; DE ANTONI, Enrico; Ulisse, Salvatore. - In: BMC CLINICAL PATHOLOGY. - ISSN 1472-6890. - ELETTRONICO. - 13:1(2013), p. 7. [10.1186/1472-6890-13-7]

Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

BALDINI, ENKE;SORRENTI, Salvatore;DI GIOIA, Cira Rosaria Tiziana;DE VITO, CORRADO;GNESSI, Lucio;CARBOTTA, GIOVANNI;DE ANTONI, Enrico;ULISSE, SALVATORE
2013

Abstract

Background: Measurement of thyroglobulin (Tg) protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C) has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN) metastasis from well-differentiated thyroid cancer (TC). In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp), Tg mRNA (FNAB-Tgm) and calcitonin (CT) mRNA (FNAB-CTm) in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods. In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC) in 26 CLN, metastatic medullary TC (MTC) in 3 CLN, metastatic anaplastic TC (ATC) in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results: The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions: We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters. © 2013 Baldini et al.; licensee BioMed Central Ltd.
2013
lymph node metastasis; fine-needle aspiration cytology; thyroid cancer; calcitonin
01 Pubblicazione su rivista::01a Articolo in rivista
Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology? / Baldini, Enke; Sorrenti, Salvatore; DI GIOIA, Cira Rosaria Tiziana; DE VITO, Corrado; Alessandro, Antonelli; Gnessi, Lucio; Carbotta, Giovanni; Eleonora, D'Armiento; Paolo, Miccoli; DE ANTONI, Enrico; Ulisse, Salvatore. - In: BMC CLINICAL PATHOLOGY. - ISSN 1472-6890. - ELETTRONICO. - 13:1(2013), p. 7. [10.1186/1472-6890-13-7]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/509769
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 44
  • ???jsp.display-item.citation.isi??? ND
social impact