Objectives: To establish the accuracy and reliability of cardiac dual-source CT (DSCT) and two-dimensional contrast-enhanced echocardiography (CE-Echo) in estimating left ventricular (LV) parameters with respect to cardiac magnetic resonance imaging (CMR) as the reference standard. Methods: Twenty-five consecutive heart transplant recipients (20 male, mean age 62.7 +/- 10.4 years, mean time since transplantation 8.1 +/- 5.9 years) were prospectively recruited. Two blinded readers independently assessed LV ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), and stroke volume (SV) for each patient after manual tracing of the endo-and epicardial contours in DSCT, CE-Echo and CMR cine images. Student's t-test for paired samples for differences, and Bland and Altman plots and Lin's concordance-correlation coefficients (CCC) for agreement were calculated. Results: There was no statistical difference between left ventricular parameters determined by DSCT and CMR. CE-Echo resulted in significant underestimation of left ventricular volumes (mean difference EDV: 15.94 +/- 14.19 ml and 17.1 +/- 17.06 ml, ESV: 8.5 +/- 9.3 and 7.32 +/- 9.14 ml with respect to DSCT and CMR), and overestimation of EF compared with the cross-sectional imaging modalities (3.78 +/- 8.47% and 2.14 +/- 8.35% with respect to DSCT and CMR). Concordance correlation coefficients for LV parameters using DSCT and CMR were higher (CCC >= 0.75) than CCC values observed between CE-Echo and DSCT- or CMR-derived data (CCC >= 0.54 and CCC >= 0.49, respectively). Interobserver agreement was higher for DSCT and CMR values (CCC >= 0.72 and CCC >= 0.87, respectively). Conclusion: In orthotopic heart transplantation cardiac DSCT allows accurate and reliable estimation of LV parameters compared with CMR, whereas CE-Echo seems to be insufficient to obtain precise measurements. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Assessment of left ventricular parameters in orthotopic heart transplant recipients using dual-source CT and contrast-enhanced echocardiography: Comparison with MRI / Maria, Arraiza; Pedro M., Azcarate; DE CECCO, CARLO NICOLA; Guillermo, Viteri; Isabel Simon, Yarza; Rafael Hernandez, Estefania; Gregorio, Rabago; Gorka, Bastarrika. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 81:11(2012), pp. 3282-3288. [10.1016/j.ejrad.2012.04.001]

Assessment of left ventricular parameters in orthotopic heart transplant recipients using dual-source CT and contrast-enhanced echocardiography: Comparison with MRI

DE CECCO, CARLO NICOLA;
2012

Abstract

Objectives: To establish the accuracy and reliability of cardiac dual-source CT (DSCT) and two-dimensional contrast-enhanced echocardiography (CE-Echo) in estimating left ventricular (LV) parameters with respect to cardiac magnetic resonance imaging (CMR) as the reference standard. Methods: Twenty-five consecutive heart transplant recipients (20 male, mean age 62.7 +/- 10.4 years, mean time since transplantation 8.1 +/- 5.9 years) were prospectively recruited. Two blinded readers independently assessed LV ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), and stroke volume (SV) for each patient after manual tracing of the endo-and epicardial contours in DSCT, CE-Echo and CMR cine images. Student's t-test for paired samples for differences, and Bland and Altman plots and Lin's concordance-correlation coefficients (CCC) for agreement were calculated. Results: There was no statistical difference between left ventricular parameters determined by DSCT and CMR. CE-Echo resulted in significant underestimation of left ventricular volumes (mean difference EDV: 15.94 +/- 14.19 ml and 17.1 +/- 17.06 ml, ESV: 8.5 +/- 9.3 and 7.32 +/- 9.14 ml with respect to DSCT and CMR), and overestimation of EF compared with the cross-sectional imaging modalities (3.78 +/- 8.47% and 2.14 +/- 8.35% with respect to DSCT and CMR). Concordance correlation coefficients for LV parameters using DSCT and CMR were higher (CCC >= 0.75) than CCC values observed between CE-Echo and DSCT- or CMR-derived data (CCC >= 0.54 and CCC >= 0.49, respectively). Interobserver agreement was higher for DSCT and CMR values (CCC >= 0.72 and CCC >= 0.87, respectively). Conclusion: In orthotopic heart transplantation cardiac DSCT allows accurate and reliable estimation of LV parameters compared with CMR, whereas CE-Echo seems to be insufficient to obtain precise measurements. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
2012
computed tomography scanner; contrast echocardiography; heart; heart function tests; magnetic resonance imaging; x-ray
01 Pubblicazione su rivista::01a Articolo in rivista
Assessment of left ventricular parameters in orthotopic heart transplant recipients using dual-source CT and contrast-enhanced echocardiography: Comparison with MRI / Maria, Arraiza; Pedro M., Azcarate; DE CECCO, CARLO NICOLA; Guillermo, Viteri; Isabel Simon, Yarza; Rafael Hernandez, Estefania; Gregorio, Rabago; Gorka, Bastarrika. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 81:11(2012), pp. 3282-3288. [10.1016/j.ejrad.2012.04.001]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/509385
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact