The space conditioning sector is one of the highest energy consumers and of the least efficient from the point of view of primary-to-end-use matching. In spite of the emergence, in the last decade, of innovative technical solutions based on renewable energy converters, installation of "new" devices without considering the whole picture (building + air conditioning system + energy conversion and supply chain) will hardly remedy the current situation. This study proposes a systemic approach to the joint design-and-analysis of space conditioning that leads to the identification of the thermodynamically most convenient configurations by integrating thermal building dissipation modeling, thermal consumption simulation and exergy efficiency calculation. The first step is the modeling of thermal characteristics of the building: the obtained temperature maps within the room are then used to compute, for each type of heating element, the actual thermal power required to ensure comfortable indoor temperature. The second step is the simulation of the "external" plant providing the prescribed thermal power, and is carried out by means of a process simulator: such a "global" simulation enables designers and decision makers to compare several feasible different combinations of internal and external systems and to identify the most exergetically convenient pairings. (C) 2013 Elsevier B.V. All rights reserved.

An integrated exergy approach for the optimal matching of internal and external heating plants in building conditioning systems / Cheremnykh, Ekaterina; Cianfrini, Marta; Sciubba, Enrico; Toro, Claudia. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 62:(2013), pp. 638-647. [10.1016/j.enbuild.2013.02.014]

An integrated exergy approach for the optimal matching of internal and external heating plants in building conditioning systems

Marta Cianfrini;Enrico Sciubba;Claudia Toro
2013

Abstract

The space conditioning sector is one of the highest energy consumers and of the least efficient from the point of view of primary-to-end-use matching. In spite of the emergence, in the last decade, of innovative technical solutions based on renewable energy converters, installation of "new" devices without considering the whole picture (building + air conditioning system + energy conversion and supply chain) will hardly remedy the current situation. This study proposes a systemic approach to the joint design-and-analysis of space conditioning that leads to the identification of the thermodynamically most convenient configurations by integrating thermal building dissipation modeling, thermal consumption simulation and exergy efficiency calculation. The first step is the modeling of thermal characteristics of the building: the obtained temperature maps within the room are then used to compute, for each type of heating element, the actual thermal power required to ensure comfortable indoor temperature. The second step is the simulation of the "external" plant providing the prescribed thermal power, and is carried out by means of a process simulator: such a "global" simulation enables designers and decision makers to compare several feasible different combinations of internal and external systems and to identify the most exergetically convenient pairings. (C) 2013 Elsevier B.V. All rights reserved.
2013
exergy efficiency; final energy use; green buildings; source/end-use matching; space conditioning
01 Pubblicazione su rivista::01a Articolo in rivista
An integrated exergy approach for the optimal matching of internal and external heating plants in building conditioning systems / Cheremnykh, Ekaterina; Cianfrini, Marta; Sciubba, Enrico; Toro, Claudia. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 62:(2013), pp. 638-647. [10.1016/j.enbuild.2013.02.014]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/509357
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 5
social impact