Operation of the central portion of Virgo as a simple 6 in Michelson interferometer has given the first demonstration of the possibility to control an interferometer suspended from Virgo full scale multistage seismic attenuators using information derived from the interferometer locking signal. A special role in the control is played by the first stage of these suspensions, an inverted pendulum: besides its seismic preisolation action, this stage has positioning dynamics of several mm, and it allows to exert a very low frequency control at the tipper level of the suspension using the interferometer fringe signal. The application of this feedback to the top-stage of the suspension allows corrections of drifts, such as tidal ones, at a stage of the suspension where a large dynamic range in displacements is available, without introducing noise at the level of the mirror, resulting in a significant reduction of the lock keeping force applied directly on the mirror at the lowest stage of the attenuator. (C) 2003 Elsevier B.V. All rights reserved.

First locking of the Virgo central area interferometer with suspension hierarchical control / Acernese, F.; Amico, P.; Arnaud, N.; Babusci, D.; Barille, R.; Barone, F.; Barsotti, L.; Barsuglia, M.; Beauville, F.; Bizouard, M. A.; Boccara, C.; Bondu, F.; Bosi, L.; Bradaschia, C.; Bracci, L.; Braccini, S.; Brillet, A.; Brisson, V.; Brocco, L.; Buskulic, D.; Calamai, G.; Calloni, E.; Campagna, E.; Cavalier, F.; Cella, G.; Chassande Mottin, E.; Cleva, F.; Cokelaer, T.; Conforto, G.; Corda, C.; Coulon, J. P.; Cuoco, E.; Dattilo, V.; Davier, M.; De Rosa, R.; Di Fiore, L.; Di Virgilio, A.; Dujardin, B.; Eleuteri, A.; Enard, D.; Ferrante, I.; Fidecaro, F.; Fiori, I.; Flaminio, R.; Fournier, J. D.; Frasca, Sergio; Frasconi, F.; Gammaitoni, L.; Gennai, A.; Giazotto, A.; Giordano, G.; Guidi, G.; Heitmann, H.; Hello, P.; Heusse, P.; Holloway, L.; Kreckelberg, S.; La Penna, P.; Loriette, V.; Loupias, M.; Losurdo, G.; Mackowski, J. M.; Majorana, E.; Man, C. N.; Marion, F.; Martelli, F.; Masserot, A.; Massonnet, L.; Mazzoni, M.; Milano, L.; Moreau, J.; Moreau, F.; Morgado, N.; Mornet, F.; Mours, B.; Pacheco, J.; Pai, A.; Palomba, C.; Paoletti, F.; Passaquieti, R.; Passuello, D.; Perniola, B.; Pinard, L.; Poggiani, R.; Punturo, M.; Puppo, P.; Qipiani, K.; Ramonet, J.; Rapagnani, Piero; Reita, V.; Remillieux, A.; Ricci, Fulvio; Ricciardi, I.; Russo, G.; Solimeno, S.; Stanga, R.; Toncelli, A.; Tonelli, M.; Tournefier, E.; Travasso, F.; Trinquet, H.; Varvella, M.; Verkindt, D.; Vetrano, F.; Veziant, O.; Vicere, A.; Vinet, J. Y.; Vocca, H.; Yvert, M.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - STAMPA. - 20:6(2004), pp. 629-640. [10.1016/j.astropartphys.2003.10.003]

First locking of the Virgo central area interferometer with suspension hierarchical control

FRASCA, Sergio;E. Majorana;RAPAGNANI, Piero;RICCI, Fulvio;
2004

Abstract

Operation of the central portion of Virgo as a simple 6 in Michelson interferometer has given the first demonstration of the possibility to control an interferometer suspended from Virgo full scale multistage seismic attenuators using information derived from the interferometer locking signal. A special role in the control is played by the first stage of these suspensions, an inverted pendulum: besides its seismic preisolation action, this stage has positioning dynamics of several mm, and it allows to exert a very low frequency control at the tipper level of the suspension using the interferometer fringe signal. The application of this feedback to the top-stage of the suspension allows corrections of drifts, such as tidal ones, at a stage of the suspension where a large dynamic range in displacements is available, without introducing noise at the level of the mirror, resulting in a significant reduction of the lock keeping force applied directly on the mirror at the lowest stage of the attenuator. (C) 2003 Elsevier B.V. All rights reserved.
2004
astrofisica; control systems; gravitational waves detectors; interferometer; interferometri; onde gravitazionali; servo and control equipment; vibration isolation
01 Pubblicazione su rivista::01a Articolo in rivista
First locking of the Virgo central area interferometer with suspension hierarchical control / Acernese, F.; Amico, P.; Arnaud, N.; Babusci, D.; Barille, R.; Barone, F.; Barsotti, L.; Barsuglia, M.; Beauville, F.; Bizouard, M. A.; Boccara, C.; Bondu, F.; Bosi, L.; Bradaschia, C.; Bracci, L.; Braccini, S.; Brillet, A.; Brisson, V.; Brocco, L.; Buskulic, D.; Calamai, G.; Calloni, E.; Campagna, E.; Cavalier, F.; Cella, G.; Chassande Mottin, E.; Cleva, F.; Cokelaer, T.; Conforto, G.; Corda, C.; Coulon, J. P.; Cuoco, E.; Dattilo, V.; Davier, M.; De Rosa, R.; Di Fiore, L.; Di Virgilio, A.; Dujardin, B.; Eleuteri, A.; Enard, D.; Ferrante, I.; Fidecaro, F.; Fiori, I.; Flaminio, R.; Fournier, J. D.; Frasca, Sergio; Frasconi, F.; Gammaitoni, L.; Gennai, A.; Giazotto, A.; Giordano, G.; Guidi, G.; Heitmann, H.; Hello, P.; Heusse, P.; Holloway, L.; Kreckelberg, S.; La Penna, P.; Loriette, V.; Loupias, M.; Losurdo, G.; Mackowski, J. M.; Majorana, E.; Man, C. N.; Marion, F.; Martelli, F.; Masserot, A.; Massonnet, L.; Mazzoni, M.; Milano, L.; Moreau, J.; Moreau, F.; Morgado, N.; Mornet, F.; Mours, B.; Pacheco, J.; Pai, A.; Palomba, C.; Paoletti, F.; Passaquieti, R.; Passuello, D.; Perniola, B.; Pinard, L.; Poggiani, R.; Punturo, M.; Puppo, P.; Qipiani, K.; Ramonet, J.; Rapagnani, Piero; Reita, V.; Remillieux, A.; Ricci, Fulvio; Ricciardi, I.; Russo, G.; Solimeno, S.; Stanga, R.; Toncelli, A.; Tonelli, M.; Tournefier, E.; Travasso, F.; Trinquet, H.; Varvella, M.; Verkindt, D.; Vetrano, F.; Veziant, O.; Vicere, A.; Vinet, J. Y.; Vocca, H.; Yvert, M.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - STAMPA. - 20:6(2004), pp. 629-640. [10.1016/j.astropartphys.2003.10.003]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/505097
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 14
social impact