The sonication technique has been shown to be a promising tool for microbiological diagnosis of device-related infections. We evaluated the usefulness of the sonication method for pathogen detection in 80 explanted cardiac components collected from 40 patients, and the results were compared with those of conventional cultures. Forty subjects undergoing cardiac device removal were studied: 20 had cardiac device infection, and 20 subjects underwent elective generator replacement or revision in the absence of infection. Sonication of explanted devices was more sensitive than traditional culture for microbial detection (67% and 50%, respectively; P = 0.0005). The bacterial count detected in sonication fluid culture was significantly higher than that detected in traditional culture in both infected (P = 0.019) and uninfected (P = 0.029) devices. In the infected patients, sonication fluid culture yielded a significantly higher rate of pathogen detection in explanted electrodes than traditional culture (65% versus 45%; P = 0.02), while no differences were found in the generators. Ten strains were detected only through sonication fluid culture: 6 Staphylococcus epidermidis strains, 1 Staphylococcus hominis strain, 2 Corynebacterium striatum strains, and 1 Bre-vundimonas sp. Neither the type nor the duration of antimicrobial therapy before device removal had an effect on the diagnostic performance of sonication fluid culture (P = 0.75 and P = 0.56, respectively). In the patients without infection, sonication fluid culture was positive in 8 cases (40%), whereas conventional culture was positive in only 4 (20%). In summary, the sonication technique improves the microbiological diagnosis of explanted cardiac devices.

Sonication of Explanted Cardiac Implants Improves Microbial Detection in Cardiac Device Infections / Oliva, Alessandra; Nguyen, BICH LIEN; Mascellino, Maria Teresa; D'Abramo, Alessandra; Iannetta, Marco; Ciccaglioni, Antonio; Vullo, Vincenzo; Mastroianni, Claudio Maria. - In: JOURNAL OF CLINICAL MICROBIOLOGY. - ISSN 0095-1137. - STAMPA. - 51:2(2013), pp. 496-502. [10.1128/jcm.02230-12]

Sonication of Explanted Cardiac Implants Improves Microbial Detection in Cardiac Device Infections

OLIVA, ALESSANDRA;NGUYEN, BICH LIEN;MASCELLINO, Maria Teresa;D'ABRAMO, ALESSANDRA;IANNETTA, MARCO;CICCAGLIONI, Antonio;VULLO, Vincenzo;MASTROIANNI, Claudio Maria
2013

Abstract

The sonication technique has been shown to be a promising tool for microbiological diagnosis of device-related infections. We evaluated the usefulness of the sonication method for pathogen detection in 80 explanted cardiac components collected from 40 patients, and the results were compared with those of conventional cultures. Forty subjects undergoing cardiac device removal were studied: 20 had cardiac device infection, and 20 subjects underwent elective generator replacement or revision in the absence of infection. Sonication of explanted devices was more sensitive than traditional culture for microbial detection (67% and 50%, respectively; P = 0.0005). The bacterial count detected in sonication fluid culture was significantly higher than that detected in traditional culture in both infected (P = 0.019) and uninfected (P = 0.029) devices. In the infected patients, sonication fluid culture yielded a significantly higher rate of pathogen detection in explanted electrodes than traditional culture (65% versus 45%; P = 0.02), while no differences were found in the generators. Ten strains were detected only through sonication fluid culture: 6 Staphylococcus epidermidis strains, 1 Staphylococcus hominis strain, 2 Corynebacterium striatum strains, and 1 Bre-vundimonas sp. Neither the type nor the duration of antimicrobial therapy before device removal had an effect on the diagnostic performance of sonication fluid culture (P = 0.75 and P = 0.56, respectively). In the patients without infection, sonication fluid culture was positive in 8 cases (40%), whereas conventional culture was positive in only 4 (20%). In summary, the sonication technique improves the microbiological diagnosis of explanted cardiac devices.
2013
sonication technique; cardiac device infection; conventional technique
01 Pubblicazione su rivista::01a Articolo in rivista
Sonication of Explanted Cardiac Implants Improves Microbial Detection in Cardiac Device Infections / Oliva, Alessandra; Nguyen, BICH LIEN; Mascellino, Maria Teresa; D'Abramo, Alessandra; Iannetta, Marco; Ciccaglioni, Antonio; Vullo, Vincenzo; Mastroianni, Claudio Maria. - In: JOURNAL OF CLINICAL MICROBIOLOGY. - ISSN 0095-1137. - STAMPA. - 51:2(2013), pp. 496-502. [10.1128/jcm.02230-12]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/500552
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 34
social impact