The diagnosis of osteomyelitis is a challenge for diagnostic imaging. Nuclear medicine procedures including white blood cell imaging have been successfully used for the identification of bone infections. This multinational, phase III clinical study in 22 European centres was undertaken to compare anti-granulocyte imaging using the murine IgG antibody besilesomab (Scintimun) with (99m)Tc-labelled white blood cells in patients with peripheral osteomyelitis. A total of 119 patients with suspected osteomyelitis of the peripheral skeleton received (99m)Tc-besilesomab and (99m)Tc-hexamethylpropyleneamine oxime (HMPAO)-labelled white blood cells (WBCs) in random order 2-4 days apart. Planar images were acquired at 4 and 24 h after injection. All scintigraphic images were interpreted in an off-site blinded read by three experienced physicians specialized in nuclear medicine, followed by a fourth blinded reader for adjudication. In addition, clinical follow-up information was collected and a final diagnosis was provided by the investigators and an independent truth panel. Safety data including levels of human anti-mouse antibodies (HAMA) and vital signs were recorded. The agreement in diagnosis across all three readers between Scintimun and (99m)Tc-HMPAO-labelled WBCs was 0.83 (lower limit of the 95% confidence interval 0.8). Using the final diagnosis of the local investigator as a reference, Scintimun had higher sensitivity than (99m)Tc-HMPAO-labelled WBCs (74.8 vs 59.0%) at slightly lower specificity (71.8 vs 79.5%, respectively). All parameters related to patient safety (laboratory data, vital signs) did not provide evidence of an elevated risk associated with the use of Scintimun except for two cases of transient hypotension. HAMA were detected in 16 of 116 patients after scan (13.8%). Scintimun imaging is accurate, efficacious and safe in the diagnosis of peripheral bone infections and provides comparable information to (99m)Tc-HMPAO-labelled WBCs.

99mTc-besilesomab (Scintimun) in peripheral osteomyelitis: comparison with 99mTc-labelled white blood cells / W. S., Richter; V., Ivancevic; J., Meller; O., Lang; D., Le Guludec; I., Szilvazi; H., Amthauer; F., Chossat; A., Dahmane; C., Schwenke; Signore, Alberto. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7089. - STAMPA. - 38:5(2011), pp. 899-910. [10.1007/s00259-011-1731-2]

99mTc-besilesomab (Scintimun) in peripheral osteomyelitis: comparison with 99mTc-labelled white blood cells.

SIGNORE, Alberto
2011

Abstract

The diagnosis of osteomyelitis is a challenge for diagnostic imaging. Nuclear medicine procedures including white blood cell imaging have been successfully used for the identification of bone infections. This multinational, phase III clinical study in 22 European centres was undertaken to compare anti-granulocyte imaging using the murine IgG antibody besilesomab (Scintimun) with (99m)Tc-labelled white blood cells in patients with peripheral osteomyelitis. A total of 119 patients with suspected osteomyelitis of the peripheral skeleton received (99m)Tc-besilesomab and (99m)Tc-hexamethylpropyleneamine oxime (HMPAO)-labelled white blood cells (WBCs) in random order 2-4 days apart. Planar images were acquired at 4 and 24 h after injection. All scintigraphic images were interpreted in an off-site blinded read by three experienced physicians specialized in nuclear medicine, followed by a fourth blinded reader for adjudication. In addition, clinical follow-up information was collected and a final diagnosis was provided by the investigators and an independent truth panel. Safety data including levels of human anti-mouse antibodies (HAMA) and vital signs were recorded. The agreement in diagnosis across all three readers between Scintimun and (99m)Tc-HMPAO-labelled WBCs was 0.83 (lower limit of the 95% confidence interval 0.8). Using the final diagnosis of the local investigator as a reference, Scintimun had higher sensitivity than (99m)Tc-HMPAO-labelled WBCs (74.8 vs 59.0%) at slightly lower specificity (71.8 vs 79.5%, respectively). All parameters related to patient safety (laboratory data, vital signs) did not provide evidence of an elevated risk associated with the use of Scintimun except for two cases of transient hypotension. HAMA were detected in 16 of 116 patients after scan (13.8%). Scintimun imaging is accurate, efficacious and safe in the diagnosis of peripheral bone infections and provides comparable information to (99m)Tc-HMPAO-labelled WBCs.
2011
01 Pubblicazione su rivista::01a Articolo in rivista
99mTc-besilesomab (Scintimun) in peripheral osteomyelitis: comparison with 99mTc-labelled white blood cells / W. S., Richter; V., Ivancevic; J., Meller; O., Lang; D., Le Guludec; I., Szilvazi; H., Amthauer; F., Chossat; A., Dahmane; C., Schwenke; Signore, Alberto. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7089. - STAMPA. - 38:5(2011), pp. 899-910. [10.1007/s00259-011-1731-2]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/499380
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 38
social impact