The aim of this study was to investigate the natural history of the circadian rhythm of blood pressure (BP) and heart rate (HR) in 10 patients with heart failure (class IV of the New York Heart Association), who underwent heart transplantation because of primary congestive cardiomyopathy. The control group was 10 age-matched clinically healthy subjects. The BP and HR monitorings were performed before and after transplantation. Preoperatively, analysis of variance and cosinor methods validated the occurrence of a statistically significant BP and HR circadian rhythm in cardiopathic patients. Over the 4 days after surgery, both the cosinor method and serial section analysis were unable to validate a 24-h periodicity for BP and HR in patients with heart transplants. Six months after surgery, the BP and HR circadian rhythm was not detected as well. One year after transplantation, the BP and HR circadian rhythm was statistically validated. The recovery of the BP and HR circadian rhythm 1 year after heart transplantation can be regarded as a clinical sign of a reacquired susceptibility to neurovegetative chronoregulation.

Circadian rhythm of blood pressure and heart rate in cardiopathic patients before and after heart transplantation / Cugini, Pietro; Lucia, Piernatale; L., Di Palma; G., Scibilia; A. R., Cioli; B., Marino. - In: CHRONOBIOLOGY INTERNATIONAL. - ISSN 0742-0528. - STAMPA. - 10:2(1993), pp. 123-127.

Circadian rhythm of blood pressure and heart rate in cardiopathic patients before and after heart transplantation.

CUGINI, Pietro;LUCIA, Piernatale;
1993

Abstract

The aim of this study was to investigate the natural history of the circadian rhythm of blood pressure (BP) and heart rate (HR) in 10 patients with heart failure (class IV of the New York Heart Association), who underwent heart transplantation because of primary congestive cardiomyopathy. The control group was 10 age-matched clinically healthy subjects. The BP and HR monitorings were performed before and after transplantation. Preoperatively, analysis of variance and cosinor methods validated the occurrence of a statistically significant BP and HR circadian rhythm in cardiopathic patients. Over the 4 days after surgery, both the cosinor method and serial section analysis were unable to validate a 24-h periodicity for BP and HR in patients with heart transplants. Six months after surgery, the BP and HR circadian rhythm was not detected as well. One year after transplantation, the BP and HR circadian rhythm was statistically validated. The recovery of the BP and HR circadian rhythm 1 year after heart transplantation can be regarded as a clinical sign of a reacquired susceptibility to neurovegetative chronoregulation.
1993
01 Pubblicazione su rivista::01a Articolo in rivista
Circadian rhythm of blood pressure and heart rate in cardiopathic patients before and after heart transplantation / Cugini, Pietro; Lucia, Piernatale; L., Di Palma; G., Scibilia; A. R., Cioli; B., Marino. - In: CHRONOBIOLOGY INTERNATIONAL. - ISSN 0742-0528. - STAMPA. - 10:2(1993), pp. 123-127.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/496599
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact