A device based on the presence of polyphenol oxidase in potato (Solanum tuberosum) tissue was set up to determine catechol. The sensor is realized by coupling a thin slice of potato tissue with a Clark electrode capable of measuring oxygen evolution from a catechol solution. In the concentration range 2.5 X 10(-5) -2.3 X 10(-4) M there is perfect linearity between the electrode signal and catechol concentration in solution. The high stability and the reliability and reproducibility of the results, tested over a period longer than 3 months, and the sensitivity of the device towards mono- and polyphenol derivatives, allow the application of such a system in physiological and pharmacological quality control.

PLANT-TISSUE ELECTRODE FOR THE DETERMINATION OF CATECHOL / Botre', Francesco; Mazzei, Franco; Marco, Lanzi; Giampiero, Lorenti; Claudio, Botre. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - STAMPA. - 255:1(1991), pp. 59-62. [10.1016/0003-2670(91)85087-9]

PLANT-TISSUE ELECTRODE FOR THE DETERMINATION OF CATECHOL

BOTRE', Francesco;MAZZEI, Franco;
1991

Abstract

A device based on the presence of polyphenol oxidase in potato (Solanum tuberosum) tissue was set up to determine catechol. The sensor is realized by coupling a thin slice of potato tissue with a Clark electrode capable of measuring oxygen evolution from a catechol solution. In the concentration range 2.5 X 10(-5) -2.3 X 10(-4) M there is perfect linearity between the electrode signal and catechol concentration in solution. The high stability and the reliability and reproducibility of the results, tested over a period longer than 3 months, and the sensitivity of the device towards mono- and polyphenol derivatives, allow the application of such a system in physiological and pharmacological quality control.
1991
amperometry; biosensors; catechol; enzyme electrodes; plant-tissue electrodes
01 Pubblicazione su rivista::01a Articolo in rivista
PLANT-TISSUE ELECTRODE FOR THE DETERMINATION OF CATECHOL / Botre', Francesco; Mazzei, Franco; Marco, Lanzi; Giampiero, Lorenti; Claudio, Botre. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - STAMPA. - 255:1(1991), pp. 59-62. [10.1016/0003-2670(91)85087-9]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/495785
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 25
social impact