Purpose: Bacterial adhesion and colonization play a crucial function in the pathogenesis of periimplant tissue infection, which is considered the main cause of fixture loss. The aim of this study is to evaluate the differences in bacterial adhesion between a machined titanium surface, a double acid etched surface (Osseotite®) and an Osseotite surface with Nanometer-scale Discrete Crystalline Deposition (DCD™) of calcium phosphate (CaP)(Nanotite®). Methods: Surface roughness properties of each sample were determined by a laser profilometer and scanning electron microscopy (SEM) observation. Bacterial adhesion on machined, Osseotite®, and Nanotite® discs were performed using the following bacterial strains: Streptococcus mutans CCUG 35176, Streptococcus sanguis CCUG 17826, Streptococcus salivarius CCUG 11878, Actinobacillus actinomycetecomitans CCUG 37002, Porphyromonas gingivalis CCUG 2521. The assessment of bacterial adhesion was performed by comparing two methods: Total Viable Count (TVC) estimation and Confocal Laser Scanning Microscopic (CSLM) studies. Results: The surface roughness parameter increased as follows: machined<Nanotite®<Osseotite®. The attachment of all bacterial strains performed by both methods showed a significant reduction on Osseotite® and even higher on Nanotite® in comparison to machined surfaces (p<0.05). The reduction in bacterial attachment was more significant on Osseotite® and Nanotite® for A. actinomycetecomitans, S. mutans and S. sanguis than for P. gingivalis and S. salivarius strains. Conclusions: Nanotite® samples showed the lowest amount of bacterial contamination in comparison to the smoother machined and rougher Osseotite® surfaces. © 2012 Wichtig Editore.

Evaluation of bacterial adhesion on machined titanium, osseotite® and nanotite® discs / Ruggero Rodriguez Y., Baena; Carla Renata, Arciola; Selan, Laura; Rosalia, Battaglia; Marcello, Imbriani; Silvana, Rizzo; Livia, Visai. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - 35:10(2012), pp. 754-761. [10.5301/ijao.5000143]

Evaluation of bacterial adhesion on machined titanium, osseotite® and nanotite® discs

SELAN, Laura;
2012

Abstract

Purpose: Bacterial adhesion and colonization play a crucial function in the pathogenesis of periimplant tissue infection, which is considered the main cause of fixture loss. The aim of this study is to evaluate the differences in bacterial adhesion between a machined titanium surface, a double acid etched surface (Osseotite®) and an Osseotite surface with Nanometer-scale Discrete Crystalline Deposition (DCD™) of calcium phosphate (CaP)(Nanotite®). Methods: Surface roughness properties of each sample were determined by a laser profilometer and scanning electron microscopy (SEM) observation. Bacterial adhesion on machined, Osseotite®, and Nanotite® discs were performed using the following bacterial strains: Streptococcus mutans CCUG 35176, Streptococcus sanguis CCUG 17826, Streptococcus salivarius CCUG 11878, Actinobacillus actinomycetecomitans CCUG 37002, Porphyromonas gingivalis CCUG 2521. The assessment of bacterial adhesion was performed by comparing two methods: Total Viable Count (TVC) estimation and Confocal Laser Scanning Microscopic (CSLM) studies. Results: The surface roughness parameter increased as follows: machined
2012
bacterial adhesion; titanium; surface roughness
01 Pubblicazione su rivista::01a Articolo in rivista
Evaluation of bacterial adhesion on machined titanium, osseotite® and nanotite® discs / Ruggero Rodriguez Y., Baena; Carla Renata, Arciola; Selan, Laura; Rosalia, Battaglia; Marcello, Imbriani; Silvana, Rizzo; Livia, Visai. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - 35:10(2012), pp. 754-761. [10.5301/ijao.5000143]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/495596
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 10
social impact