PURPOSE: Elderly subjects often have fractures of the proximal humerus, which may be difficult to manage in patients in poor general condition. The MIROS is a new percutaneous pinning device allowing correction of angular displacement and stable fixation of fracture fragments. We evaluated the results of percutaneous fixation of three- or four-part fractures of the proximal humerus of patients in the American Society of Anesthesiologists physical status three or four treated either with MIROS or traditional percutaneous pinning (TPP). METHODS: A total of 31 patients treated with MIROS and 27 undergoing TPP were enrolled in the study. Pre-operatively anteroposterior and transthoracic or axillary radiographs were obtained in all cases and computed tomography scans in patients with the most complex fractures. Follow-up evaluations were carried out at three, six, 12 and 16 weeks, and six months, one year and two years postoperatively, using the Constant Score (CS) and subjective shoulder value (SSV) methods. RESULTS: Of the 58 patients, 52 could be evaluated at all follow-ups. In both three- or four-part fractures there were significantly higher CS and SSV scores in the MIROS compared to the TPP group at all the late follow-ups. Lower rates of deep infection, pin tract infection and pin mobilisation were found in the MIROS group (p < 0.001). In both groups there was a significant association between the final result (CS) and either the type of fracture or complications (p < 0.001). CONCLUSIONS: The MIROS resulted in better clinical results and less complications than TPP in elderly patients. This method, however, may not be indicated for younger patients in good general condition.

Percutaneous pinning of 3- or 4- part fractures of proximal humerus in elderly patients in poor general conditions: MIROS versus traditional pinning / S., Carbone; M., Tangari; Gumina, Stefano; R., Postacchini; A., Campi; Postacchini, Franco. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - STAMPA. - 13 (Suppl 1):(2012), pp. S22-S22. (Intervento presentato al convegno 97° Congresso della Società Italiana di Ortopedia e Traumatologia (SIOT) tenutosi a Rome, Italy nel 10-13 November 2012).

Percutaneous pinning of 3- or 4- part fractures of proximal humerus in elderly patients in poor general conditions: MIROS versus traditional pinning.

GUMINA, STEFANO;POSTACCHINI, Franco
2012

Abstract

PURPOSE: Elderly subjects often have fractures of the proximal humerus, which may be difficult to manage in patients in poor general condition. The MIROS is a new percutaneous pinning device allowing correction of angular displacement and stable fixation of fracture fragments. We evaluated the results of percutaneous fixation of three- or four-part fractures of the proximal humerus of patients in the American Society of Anesthesiologists physical status three or four treated either with MIROS or traditional percutaneous pinning (TPP). METHODS: A total of 31 patients treated with MIROS and 27 undergoing TPP were enrolled in the study. Pre-operatively anteroposterior and transthoracic or axillary radiographs were obtained in all cases and computed tomography scans in patients with the most complex fractures. Follow-up evaluations were carried out at three, six, 12 and 16 weeks, and six months, one year and two years postoperatively, using the Constant Score (CS) and subjective shoulder value (SSV) methods. RESULTS: Of the 58 patients, 52 could be evaluated at all follow-ups. In both three- or four-part fractures there were significantly higher CS and SSV scores in the MIROS compared to the TPP group at all the late follow-ups. Lower rates of deep infection, pin tract infection and pin mobilisation were found in the MIROS group (p < 0.001). In both groups there was a significant association between the final result (CS) and either the type of fracture or complications (p < 0.001). CONCLUSIONS: The MIROS resulted in better clinical results and less complications than TPP in elderly patients. This method, however, may not be indicated for younger patients in good general condition.
2012
97° Congresso della Società Italiana di Ortopedia e Traumatologia (SIOT)
proximal humeral fractures; Percutaneous pinning of humeral fractures; MIROS system
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Percutaneous pinning of 3- or 4- part fractures of proximal humerus in elderly patients in poor general conditions: MIROS versus traditional pinning / S., Carbone; M., Tangari; Gumina, Stefano; R., Postacchini; A., Campi; Postacchini, Franco. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - STAMPA. - 13 (Suppl 1):(2012), pp. S22-S22. (Intervento presentato al convegno 97° Congresso della Società Italiana di Ortopedia e Traumatologia (SIOT) tenutosi a Rome, Italy nel 10-13 November 2012).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/491814
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact