Many studies have analyzed the morphometry of the proximal medullary canal of the femur. The knowledge of the shape and size of the femoral canal, in fact, is necessary to obtain , in the implantation of a custom made prosthesis, the maximum fitting of the stem with the internal geometry of the femur. We studied the morphometry of the proximal medullary canal in 70 femurs obtained from cadevers, using mathematical models applied to the data obtained by measurements performed on axial CT scans and coronal scans of tridimensional reconstructions. The results were compared with those obtained by measurements on standard radiographs. We found that the median portion of the proximal extremity of the femur shows the highest degree of procurvation. On the frontal plane, the uppermost portion of the medullary canal make an inward curve cranially, and an outward curve caudally. The results of our studies indicate that no definite information on the morphometry of the proximal femoral medullary canal can be obtained from radiographs.

Morphometry of the proximal femoral canal analyzed by a new mathematical model / Postacchini, Franco; Gumina, Stefano; F., Randisi; Orsina, Luigi; S., Urso. - STAMPA. - 1:(1994), pp. 33-33. (Intervento presentato al convegno 7th Annual international symposium on custom-made prosthesis (ISSCP) tenutosi a Rome, Italy nel 5-8 October 1994).

Morphometry of the proximal femoral canal analyzed by a new mathematical model.

POSTACCHINI, Franco;GUMINA, STEFANO;ORSINA, Luigi;
1994

Abstract

Many studies have analyzed the morphometry of the proximal medullary canal of the femur. The knowledge of the shape and size of the femoral canal, in fact, is necessary to obtain , in the implantation of a custom made prosthesis, the maximum fitting of the stem with the internal geometry of the femur. We studied the morphometry of the proximal medullary canal in 70 femurs obtained from cadevers, using mathematical models applied to the data obtained by measurements performed on axial CT scans and coronal scans of tridimensional reconstructions. The results were compared with those obtained by measurements on standard radiographs. We found that the median portion of the proximal extremity of the femur shows the highest degree of procurvation. On the frontal plane, the uppermost portion of the medullary canal make an inward curve cranially, and an outward curve caudally. The results of our studies indicate that no definite information on the morphometry of the proximal femoral medullary canal can be obtained from radiographs.
1994
7th Annual international symposium on custom-made prosthesis (ISSCP)
Morphometry of the proximal femoral canal; proximal femoral canal
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Morphometry of the proximal femoral canal analyzed by a new mathematical model / Postacchini, Franco; Gumina, Stefano; F., Randisi; Orsina, Luigi; S., Urso. - STAMPA. - 1:(1994), pp. 33-33. (Intervento presentato al convegno 7th Annual international symposium on custom-made prosthesis (ISSCP) tenutosi a Rome, Italy nel 5-8 October 1994).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/489375
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact