Objectives: Aim of this study was to evaluate the cyclic fatigue resistance of two types of new nickel-titanium endodontic instruments Materials and methods: 80 instruments divided into 4 groups (20 each group), GTX 30/.06, GTX 40/.04, Twisted Files 30/.06, Twisted Files 40/.04. All the instruments were tested in two different artificial canals, one with a single curvature and the other with a double curvature. All instruments were rotated until fracture and the number of cycles to fracture (NCF) was then calculated, Results: Twisted Files instruments resisted longer in rotation in the different canals. The size of the instrument (30.06, 40.04) did not have a statistically significant influence. Conclusions: The instruments Twisted Files were more resistant to cyclic fatigue compared to the GTX. © 2012 Società Italiana di Endodonzia.

Cyclic fatigue of new nickel-titanium instruments in artificial canals with single and double curvature [Fatica ciclica di nuovi strumenti al nichel-titanio in canali artificiali a singola e doppia curvatura] / Cristiano, Miglio; Nicola Maria, Grande; Gianluca, Plotino; Valerio, Milana; Testarelli, Luca; Gambarini, Gianluca. - In: GIORNALE ITALIANO DI ENDODONZIA. - ISSN 1121-4171. - 26:3(2012), pp. 106-110. [10.1016/j.gien.2012.09.007]

Cyclic fatigue of new nickel-titanium instruments in artificial canals with single and double curvature [Fatica ciclica di nuovi strumenti al nichel-titanio in canali artificiali a singola e doppia curvatura]

TESTARELLI, Luca;GAMBARINI, Gianluca
2012

Abstract

Objectives: Aim of this study was to evaluate the cyclic fatigue resistance of two types of new nickel-titanium endodontic instruments Materials and methods: 80 instruments divided into 4 groups (20 each group), GTX 30/.06, GTX 40/.04, Twisted Files 30/.06, Twisted Files 40/.04. All the instruments were tested in two different artificial canals, one with a single curvature and the other with a double curvature. All instruments were rotated until fracture and the number of cycles to fracture (NCF) was then calculated, Results: Twisted Files instruments resisted longer in rotation in the different canals. The size of the instrument (30.06, 40.04) did not have a statistically significant influence. Conclusions: The instruments Twisted Files were more resistant to cyclic fatigue compared to the GTX. © 2012 Società Italiana di Endodonzia.
2012
cyclic fatigue; double curvature; nickel-titanium; single curvature; thermal treatments
01 Pubblicazione su rivista::01a Articolo in rivista
Cyclic fatigue of new nickel-titanium instruments in artificial canals with single and double curvature [Fatica ciclica di nuovi strumenti al nichel-titanio in canali artificiali a singola e doppia curvatura] / Cristiano, Miglio; Nicola Maria, Grande; Gianluca, Plotino; Valerio, Milana; Testarelli, Luca; Gambarini, Gianluca. - In: GIORNALE ITALIANO DI ENDODONZIA. - ISSN 1121-4171. - 26:3(2012), pp. 106-110. [10.1016/j.gien.2012.09.007]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/485100
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact