Pedulla E, Grande NM, Plotino G, Palermo F, Gambarini G, Rapisarda E. Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite. International Endodontic Journal, 46, 155-159, 2013. Aim To assess resistance to cyclic fatigue of reciprocating nickel-titanium (NiTi ) files (Reciproc and WaveOne) after immersion in NaOCl solution over several time periods. Methodology A total of 90 new Reciproc R25 and WaveOne Primary were tested. The 45 files of the same brand were randomly assigned to three groups (n = 15) and submitted to the following immersion protocol in 5% NaOCl at 37 degrees C for 16 mm: no immersion (control), 1 or 5 min dynamically. The dynamic immersion and the following cyclic fatigue tests were performed using the appropriate preset reciprocation modes ('RECIPROC ALL' or 'WAVEONE ALL') in a specially designed endodontic motor. Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60 degrees angle of curvature and 5 mm radius of curvature. The artificial canal was manufactured reproducing the instrument's size and taper. Data were analysed by 2-way analyses of variance. Results Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl . Reciproc R25 was associated with a higher cyclic fatigue resistance in all groups compared to WaveOne Primary (P < 0.0001). Conclusions Reciprocating dynamic immersion in NaOCl for 1 or 5 min did not reduce the cyclic fatigue resistance of NiTi files significantly. However, the type of reciprocating instrument influenced cyclic fatigue resistance with Reciproc R25 being more resistant than WaveOne Primary.

Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite / E., Pedulla; Grande, NICOLA MARIA; G., Plotino; F., Palermo; Gambarini, Gianluca; E., Rapisarda. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - 46:2(2013), pp. 155-159. [10.1111/j.1365-2591.2012.02100.x]

Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite

GRANDE, NICOLA MARIA;GAMBARINI, Gianluca;
2013

Abstract

Pedulla E, Grande NM, Plotino G, Palermo F, Gambarini G, Rapisarda E. Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite. International Endodontic Journal, 46, 155-159, 2013. Aim To assess resistance to cyclic fatigue of reciprocating nickel-titanium (NiTi ) files (Reciproc and WaveOne) after immersion in NaOCl solution over several time periods. Methodology A total of 90 new Reciproc R25 and WaveOne Primary were tested. The 45 files of the same brand were randomly assigned to three groups (n = 15) and submitted to the following immersion protocol in 5% NaOCl at 37 degrees C for 16 mm: no immersion (control), 1 or 5 min dynamically. The dynamic immersion and the following cyclic fatigue tests were performed using the appropriate preset reciprocation modes ('RECIPROC ALL' or 'WAVEONE ALL') in a specially designed endodontic motor. Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60 degrees angle of curvature and 5 mm radius of curvature. The artificial canal was manufactured reproducing the instrument's size and taper. Data were analysed by 2-way analyses of variance. Results Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl . Reciproc R25 was associated with a higher cyclic fatigue resistance in all groups compared to WaveOne Primary (P < 0.0001). Conclusions Reciprocating dynamic immersion in NaOCl for 1 or 5 min did not reduce the cyclic fatigue resistance of NiTi files significantly. However, the type of reciprocating instrument influenced cyclic fatigue resistance with Reciproc R25 being more resistant than WaveOne Primary.
2013
corrosion; sodium hypochlorite; cyclic fatigue; m-wire; reciprocating instruments; nickel-titanium
01 Pubblicazione su rivista::01a Articolo in rivista
Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite / E., Pedulla; Grande, NICOLA MARIA; G., Plotino; F., Palermo; Gambarini, Gianluca; E., Rapisarda. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - 46:2(2013), pp. 155-159. [10.1111/j.1365-2591.2012.02100.x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/481699
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 49
social impact