BACKGROUND: Despite significant improvements in stent platform, currently available bare-metal stents (BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving results of BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes of the novel Skylor™ stent, stratifying outcomes according to stenting technique. METHODS and RESULTS: We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centers between 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e. death, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). As pre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation. A total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparing patients undergoing direct stenting (66%) versus pre-dilation (34%) at 16±7 months of follow-up, MACE had occurred in, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2% (p=0.380), MI in 1% versus 2% (p=0.032), CABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensity adjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024]. CONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stenting technique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI. © 2012 Bentham Science Publishers.

Synergy between direct coronary stenting technique and use of the novel thin strut cobalt chromium skylor™ stent: The mace in follow up patients treated with skylor stent [MILES Study] / Arturo, Giordano; Michele, Polimeno; Nicola, Corcione; Luciano, Fattore; Luigi Di, Lorenzo; BIONDI ZOCCAI, Giuseppe; Paolo, Ferraro; M. F., Romano. - ELETTRONICO. - 8:1(2012), pp. 6-13. [10.2174/157340312801215818]

Synergy between direct coronary stenting technique and use of the novel thin strut cobalt chromium skylor™ stent: The mace in follow up patients treated with skylor stent [MILES Study]

BIONDI ZOCCAI, GIUSEPPE;
2012

Abstract

BACKGROUND: Despite significant improvements in stent platform, currently available bare-metal stents (BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving results of BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes of the novel Skylor™ stent, stratifying outcomes according to stenting technique. METHODS and RESULTS: We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centers between 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e. death, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). As pre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation. A total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparing patients undergoing direct stenting (66%) versus pre-dilation (34%) at 16±7 months of follow-up, MACE had occurred in, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2% (p=0.380), MI in 1% versus 2% (p=0.032), CABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensity adjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024]. CONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stenting technique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI. © 2012 Bentham Science Publishers.
2012
angioplasty; restenosis; stents
01 Pubblicazione su rivista::01a Articolo in rivista
Synergy between direct coronary stenting technique and use of the novel thin strut cobalt chromium skylor™ stent: The mace in follow up patients treated with skylor stent [MILES Study] / Arturo, Giordano; Michele, Polimeno; Nicola, Corcione; Luciano, Fattore; Luigi Di, Lorenzo; BIONDI ZOCCAI, Giuseppe; Paolo, Ferraro; M. F., Romano. - ELETTRONICO. - 8:1(2012), pp. 6-13. [10.2174/157340312801215818]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/479989
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact