An electrothermal sample vaporization device was combined with an inductively coupled plasma spectrometer for the determination of Pt in biological samples (serum, urine, tissues). A commercial graphite furnace for atomic absorption was connected to an ICP torch using an electrically heated quartz tube. The argon gas stream was slightly modified. Sample aliquots up to 100 microL were dried at 120 degrees C, ashed at 1400 degrees C and subsequently heated to 2700 degrees C. The aerosol obtained was transported into a 2.2 kW argon ICP by means of a carrier gas flowing at 1.4 L/min. The detection limit was found to be 0.25-0.5 micrograms/L, depending upon the matrix. These values are one order of magnitude better than those obtained using conventional nebulizers. The precision (RSD) at 50 micrograms/L ranged from 0.04 to 0.07 and the accuracy (evaluated as recovery) was 103.2% to 105.3%. Because the matrix effects could not be neglected, different calibration curves were prepared for each kind of medium. The analytical capabilities of the method described were found to be suitable for the determination of Pt used in routine monitoring during chemotherapy with Cisplatin and other Pt-based compounds.

Determination of Pt in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) with electrothermal vaporization (ETV) / A., Alimonti; F., Petrucci; Dominici, Carlo; S., Caroli. - In: JOURNAL TRACE ELEMENTS ELECTROLYTES IN HEALTH AND DISEASE. - ISSN 0931-2838. - STAMPA. - 1:2(1987), pp. 79-83.

Determination of Pt in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) with electrothermal vaporization (ETV).

DOMINICI, Carlo;
1987

Abstract

An electrothermal sample vaporization device was combined with an inductively coupled plasma spectrometer for the determination of Pt in biological samples (serum, urine, tissues). A commercial graphite furnace for atomic absorption was connected to an ICP torch using an electrically heated quartz tube. The argon gas stream was slightly modified. Sample aliquots up to 100 microL were dried at 120 degrees C, ashed at 1400 degrees C and subsequently heated to 2700 degrees C. The aerosol obtained was transported into a 2.2 kW argon ICP by means of a carrier gas flowing at 1.4 L/min. The detection limit was found to be 0.25-0.5 micrograms/L, depending upon the matrix. These values are one order of magnitude better than those obtained using conventional nebulizers. The precision (RSD) at 50 micrograms/L ranged from 0.04 to 0.07 and the accuracy (evaluated as recovery) was 103.2% to 105.3%. Because the matrix effects could not be neglected, different calibration curves were prepared for each kind of medium. The analytical capabilities of the method described were found to be suitable for the determination of Pt used in routine monitoring during chemotherapy with Cisplatin and other Pt-based compounds.
1987
01 Pubblicazione su rivista::01a Articolo in rivista
Determination of Pt in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) with electrothermal vaporization (ETV) / A., Alimonti; F., Petrucci; Dominici, Carlo; S., Caroli. - In: JOURNAL TRACE ELEMENTS ELECTROLYTES IN HEALTH AND DISEASE. - ISSN 0931-2838. - STAMPA. - 1:2(1987), pp. 79-83.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/477718
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 18
  • ???jsp.display-item.citation.isi??? ND
social impact