Background: To compare the usefulness of the traditional pattern-reversal Visual Evoked Potentials (VEP) with multifocal VEP (mfVEP) and Frequency-Doubling Technology (FDT) perimetry in the evaluation of the ocular abnormalities induced by acute or subacute Optic Neuritis (ON). Methods: The test results of twenty-four ON patients were compared with those obtained in 40 normal control subjects. MfVEP recordings were obtained by using an Optoelectronic Stimulator that extracts topographic VEP using a pseudorandom m-sequence stimulus. Receiver operator characteristic (ROC) curves were calculated to determine the sensitivity and specificity of abnormal values. Results: The frequency of the abnormal ocular findings differed in the ON patients according to the used technique. Reduced visual sensitivity was demonstrated in 12 eyes (54.5%) using the FDT perimetry; 17 eyes (77.2%) showed decreased amplitude and/or an increase in the implicit time of the P1 wave in the mfVEP and 20 eyes (90.9%) showed an abnormal decrease in the amplitude and/or an increase in the latency of the P100 peak at VEP examination. The areas under the ROC curves ranged from 0.743 to 0.935, with VEP having the largest areas. The VEP and mfVEP amplitudes and latencies yielded the greatest sensitivity and specificity. Conclusions: The mfVEP and the FDT perimetry can be used for the evaluation and monitoring of visual impairment in patients with ON. The most sensitive and practical diagnostic tool in patients with ON is, however, the traditional VEP. The mfVEP can be utilised in those cases with doubtful or negative VEP results.

Multifocal and pattern-reversal VEP vs. automated perimetry FDT Matrix in optic neuritis / Nebbioso, M.; Steigerwalt, R. D.; PECORI GIRALDI, Maria Jose'; Vingolo, Enzo M.. - In: INDIAN JOURNAL OF OPHTHALMOLOGY. - ISSN 0301-4738. - STAMPA. - 61:2(2013), pp. 59-64. [10.4103/0301-4738.99638]

Multifocal and pattern-reversal VEP vs. automated perimetry FDT Matrix in optic neuritis.

M. Nebbioso
;
PECORI GIRALDI, Maria Jose';Enzo M. Vingolo
2013

Abstract

Background: To compare the usefulness of the traditional pattern-reversal Visual Evoked Potentials (VEP) with multifocal VEP (mfVEP) and Frequency-Doubling Technology (FDT) perimetry in the evaluation of the ocular abnormalities induced by acute or subacute Optic Neuritis (ON). Methods: The test results of twenty-four ON patients were compared with those obtained in 40 normal control subjects. MfVEP recordings were obtained by using an Optoelectronic Stimulator that extracts topographic VEP using a pseudorandom m-sequence stimulus. Receiver operator characteristic (ROC) curves were calculated to determine the sensitivity and specificity of abnormal values. Results: The frequency of the abnormal ocular findings differed in the ON patients according to the used technique. Reduced visual sensitivity was demonstrated in 12 eyes (54.5%) using the FDT perimetry; 17 eyes (77.2%) showed decreased amplitude and/or an increase in the implicit time of the P1 wave in the mfVEP and 20 eyes (90.9%) showed an abnormal decrease in the amplitude and/or an increase in the latency of the P100 peak at VEP examination. The areas under the ROC curves ranged from 0.743 to 0.935, with VEP having the largest areas. The VEP and mfVEP amplitudes and latencies yielded the greatest sensitivity and specificity. Conclusions: The mfVEP and the FDT perimetry can be used for the evaluation and monitoring of visual impairment in patients with ON. The most sensitive and practical diagnostic tool in patients with ON is, however, the traditional VEP. The mfVEP can be utilised in those cases with doubtful or negative VEP results.
2013
Frequency-Doubling Technology perimetry; multifocal VEP; Optic Neuritis; pattern-reversal VEP
01 Pubblicazione su rivista::01a Articolo in rivista
Multifocal and pattern-reversal VEP vs. automated perimetry FDT Matrix in optic neuritis / Nebbioso, M.; Steigerwalt, R. D.; PECORI GIRALDI, Maria Jose'; Vingolo, Enzo M.. - In: INDIAN JOURNAL OF OPHTHALMOLOGY. - ISSN 0301-4738. - STAMPA. - 61:2(2013), pp. 59-64. [10.4103/0301-4738.99638]
File allegati a questo prodotto
File Dimensione Formato  
Nebbioso_Multifocal_2013.pdf

solo gestori archivio

Note: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3638327/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 858.53 kB
Formato Adobe PDF
858.53 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/475912
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact