In this relatively simple, rapid assay of estriol-16 alpha-glucuronide in pregnancy urine, the urine sample is diluted 20-fold with phosphate buffer (pH 5.2) containing 360 mL of acetonitrile and 2 g of cetyltrimethylammonium bromide per liter, then directly injected into the chromatograph. A sample can be assayed within 14 min. Day-to-day CVs ranged from 2.3% at 45 mg/L to 2.9% at 4.8 mg/L. The limit of sensitivity is 0.4 mg/L. Results by the present method (y) correlated and compared very well with those by a method involving fractionation of estrogen conjugates and gas chromatography (x) for 24 samples of pregnancy urine (y = 1.09x + 0.303; r = 0.947). This assay is inexpensive and suitable for complete automation.

Improved determination of estriol 16 alpha glucuronide in pregnancy urine by direct liquid chromatography with fluorescence detection / F., Andreolini; C., Borra; DI CORCIA, Antonio; Samperi, Roberto; Raponi, Giammarco. - In: CLINICAL CHEMISTRY. - ISSN 1056-599X. - STAMPA. - 31:1(1985), pp. 124-126.

Improved determination of estriol 16 alpha glucuronide in pregnancy urine by direct liquid chromatography with fluorescence detection.

DI CORCIA, Antonio;SAMPERI, Roberto;RAPONI, Giammarco
1985

Abstract

In this relatively simple, rapid assay of estriol-16 alpha-glucuronide in pregnancy urine, the urine sample is diluted 20-fold with phosphate buffer (pH 5.2) containing 360 mL of acetonitrile and 2 g of cetyltrimethylammonium bromide per liter, then directly injected into the chromatograph. A sample can be assayed within 14 min. Day-to-day CVs ranged from 2.3% at 45 mg/L to 2.9% at 4.8 mg/L. The limit of sensitivity is 0.4 mg/L. Results by the present method (y) correlated and compared very well with those by a method involving fractionation of estrogen conjugates and gas chromatography (x) for 24 samples of pregnancy urine (y = 1.09x + 0.303; r = 0.947). This assay is inexpensive and suitable for complete automation.
1985
01 Pubblicazione su rivista::01a Articolo in rivista
Improved determination of estriol 16 alpha glucuronide in pregnancy urine by direct liquid chromatography with fluorescence detection / F., Andreolini; C., Borra; DI CORCIA, Antonio; Samperi, Roberto; Raponi, Giammarco. - In: CLINICAL CHEMISTRY. - ISSN 1056-599X. - STAMPA. - 31:1(1985), pp. 124-126.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/474390
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
social impact