Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
The ANTARES neutrino telescope, located 40km off the coast of Toulon in the Mediterranean Sea at a mooring depth of about 2475m, consists of twelve detection lines equipped typically with 25 storeys. Every storey carries three optical modules that detect Cherenkov light induced by charged secondary particles (typically muons) coming from neutrino interactions. As these lines are flexible structures fixed to the sea bed and held taut by a buoy, sea currents cause the lines to move and the storeys to rotate. The knowledge of the position of the optical modules with a precision better than 10cm is essential for a good reconstruction of particle tracks. In this paper the ANTARES positioning system is described. It consists of an acoustic positioning system, for distance triangulation, and a compass-tiltmeter system, for the measurement of the orientation and inclination of the storeys. Necessary corrections are discussed and the results of the detector alignment procedure are described.
The positioning system of the ANTARES Neutrino Telescope / S., Adrian Martinez; M., Ageron; J. a., Aguilar; I., Al Samarai; A., Albert; M., Andre; M., Anghinolfi; G., Anton; S., Anvar; M., Ardid; A. c., Assis Jesus; T., Astraatmadja; J. J., Aubert; B., Baret; S., Basa; V., Bertin; S., Biagi; A., Bigi; C., Bigongiari; C., Bogazzi; M., Bou Cabo; B., Bouhou; M. c., Bouwhuis; J., Brunner; J., Busto; F., Camarena; Capone, Antonio; C., Carloganu; G., Carminati; J., Carr; S., Cecchini; Z., Charif; Ph, Charvis; T., Chiarusi; M., Circella; R., Coniglione; H., Costantini; P., Coyle; C., Curtil; DE BONIS, Giulia; M. p., Decowski; I., Dekeyser; A., Deschamps; C., Distefano; C., Donzaud; D., Dornic; Q., Dorosti; D., Drouhin; T., Eberl; U., Emanuele; A., Enzenhofer; J. P., Ernenwein; S., Escoffier; Fermani, Paolo; M., Ferri; V., Flaminio; F., Folger; U., Fritsch; J. L., Fuda; S., Galata; P., Gay; G., Giacomelli; V., Giordano; J. p., Gomez Gonzalez; K., Graf; G., Guillard; G., Halladjian; G., Hallewell; H., Van Haren; J., Hartman; A. j., Heijboer; Y., Hello; J. j., Hernandez Rey; B., Herold; J., Hol; J., Hossl; C. c., Hsu; M., De Jong; M., Kadler; O., Kalekin; A., Kappes; U., Katz; O., Kavatsyuk; P., Keller; P., Kooijman; C., Kopper; A., Kouchner; I., Kreykenbohm; V., Kulikovskiy; R., Lahmann; P., Lamare; G., Larosa; D., Lattuada; D., Lefevre; A., Le Van Suu; G., Lim; D., Lo Presti; H., Loehner; S., Loucatos; S., Mangano; M., Marcelin; A., Margiotta; J. a., Martinez Mora; A., Meli; T., Montaruli; L., Moscoso; H., Motz; M., Neff; E., Nezri; V., Niess; D., Palioselitis; G. e., Pavalas; K., Payet; P., Payre; J., Petrovic; P., Piattelli; N., Picot Clemente; V., Popa; T., Pradier; E., Presani; C., Racca; D., Real; C., Reed; G., Riccobene; C., Richardt; R., Richter; C., Riviere; A., Robert; K., Roensch; A., Rostovtsev; J., Ruiz Rivas; M., Rujoiu; G. v., Russo; F., Salesa; D. f. e., Samtleben; F., Schock; J. P., Schuller; F., Schussler; T., Seitz; R., Shanidze; Simeone, Francesco; A., Spies; M., Spurio; J. j. m., Steijger; Th, Stolarczyk; A., Sanchez Losa; M., Taiuti; C., Tamburini; S., Toscano; B., Vallage; V., Van Elewyck; G., Vannoni; M., Vecchi; P., Vernin; S., Wagner; G., Wijnker; J., Wilms; E., De Wolf; H., Yepes; D., Zaborov; J. d., Zornoza; J., Zuniga. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - STAMPA. - 7:8(2012), pp. T08002-T08002. [10.1088/1748-0221/7/08/t08002]
The positioning system of the ANTARES Neutrino Telescope
S. Adrian Martinez;M. Ageron;J. a. Aguilar;I. Al Samarai;A. Albert;M. Andre;M. Anghinolfi;G. Anton;S. Anvar;M. Ardid;A. c. Assis Jesus;T. Astraatmadja;J. J. Aubert;B. Baret;S. Basa;V. Bertin;S. Biagi;A. Bigi;C. Bigongiari;C. Bogazzi;M. Bou Cabo;B. Bouhou;M. c. Bouwhuis;J. Brunner;J. Busto;F. Camarena;CAPONE, Antonio;C. Carloganu;G. Carminati;J. Carr;S. Cecchini;Z. Charif;Ph Charvis;T. Chiarusi;M. Circella;R. Coniglione;H. Costantini;P. Coyle;C. Curtil;DE BONIS, Giulia;M. p. Decowski;I. Dekeyser;A. Deschamps;C. Distefano;C. Donzaud;D. Dornic;Q. Dorosti;D. Drouhin;T. Eberl;U. Emanuele;A. Enzenhofer;J. P. Ernenwein;S. Escoffier;FERMANI, PAOLO;M. Ferri;V. Flaminio;F. Folger;U. Fritsch;J. L. Fuda;S. Galata;P. Gay;G. Giacomelli;V. Giordano;J. p. Gomez Gonzalez;K. Graf;G. Guillard;G. Halladjian;G. Hallewell;H. Van Haren;J. Hartman;A. j. Heijboer;Y. Hello;J. j. Hernandez Rey;B. Herold;J. Hol;J. Hossl;C. c. Hsu;M. De Jong;M. Kadler;O. Kalekin;A. Kappes;U. Katz;O. Kavatsyuk;P. Keller;P. Kooijman;C. Kopper;A. Kouchner;I. Kreykenbohm;V. Kulikovskiy;R. Lahmann;P. Lamare;G. Larosa;D. Lattuada;D. Lefevre;A. Le Van Suu;G. Lim;D. Lo Presti;H. Loehner;S. Loucatos;S. Mangano;M. Marcelin;A. Margiotta;J. a. Martinez Mora;A. Meli;T. Montaruli;L. Moscoso;H. Motz;M. Neff;E. Nezri;V. Niess;D. Palioselitis;G. e. Pavalas;K. Payet;P. Payre;J. Petrovic;P. Piattelli;N. Picot Clemente;V. Popa;T. Pradier;E. Presani;C. Racca;D. Real;C. Reed;G. Riccobene;C. Richardt;R. Richter;C. Riviere;A. Robert;K. Roensch;A. Rostovtsev;J. Ruiz Rivas;M. Rujoiu;G. v. Russo;F. Salesa;D. f. e. Samtleben;F. Schock;J. P. Schuller;F. Schussler;T. Seitz;R. Shanidze;SIMEONE, Francesco;A. Spies;M. Spurio;J. j. m. Steijger;Th Stolarczyk;A. Sanchez Losa;M. Taiuti;C. Tamburini;S. Toscano;B. Vallage;V. Van Elewyck;G. Vannoni;M. Vecchi;P. Vernin;S. Wagner;G. Wijnker;J. Wilms;E. De Wolf;H. Yepes;D. Zaborov;J. d. Zornoza;J. Zuniga
2012
Abstract
The ANTARES neutrino telescope, located 40km off the coast of Toulon in the Mediterranean Sea at a mooring depth of about 2475m, consists of twelve detection lines equipped typically with 25 storeys. Every storey carries three optical modules that detect Cherenkov light induced by charged secondary particles (typically muons) coming from neutrino interactions. As these lines are flexible structures fixed to the sea bed and held taut by a buoy, sea currents cause the lines to move and the storeys to rotate. The knowledge of the position of the optical modules with a precision better than 10cm is essential for a good reconstruction of particle tracks. In this paper the ANTARES positioning system is described. It consists of an acoustic positioning system, for distance triangulation, and a compass-tiltmeter system, for the measurement of the orientation and inclination of the storeys. Necessary corrections are discussed and the results of the detector alignment procedure are described.
detector modelling and simulations ii (electric fields; antares neutrino telescope; multiplication and induction; charge transport; pulse formation; electron emission; etc); hardware; architecture; timing detectors; detector control systems (detector and experiment monitoring and slow-control systems; algorithms; databases); sources; detector alignment; calibration.; acoustic positioning; detector alignment and calibration methods (lasers; particle-beams)
01 Pubblicazione su rivista::01a Articolo in rivista
The positioning system of the ANTARES Neutrino Telescope / S., Adrian Martinez; M., Ageron; J. a., Aguilar; I., Al Samarai; A., Albert; M., Andre; M., Anghinolfi; G., Anton; S., Anvar; M., Ardid; A. c., Assis Jesus; T., Astraatmadja; J. J., Aubert; B., Baret; S., Basa; V., Bertin; S., Biagi; A., Bigi; C., Bigongiari; C., Bogazzi; M., Bou Cabo; B., Bouhou; M. c., Bouwhuis; J., Brunner; J., Busto; F., Camarena; Capone, Antonio; C., Carloganu; G., Carminati; J., Carr; S., Cecchini; Z., Charif; Ph, Charvis; T., Chiarusi; M., Circella; R., Coniglione; H., Costantini; P., Coyle; C., Curtil; DE BONIS, Giulia; M. p., Decowski; I., Dekeyser; A., Deschamps; C., Distefano; C., Donzaud; D., Dornic; Q., Dorosti; D., Drouhin; T., Eberl; U., Emanuele; A., Enzenhofer; J. P., Ernenwein; S., Escoffier; Fermani, Paolo; M., Ferri; V., Flaminio; F., Folger; U., Fritsch; J. L., Fuda; S., Galata; P., Gay; G., Giacomelli; V., Giordano; J. p., Gomez Gonzalez; K., Graf; G., Guillard; G., Halladjian; G., Hallewell; H., Van Haren; J., Hartman; A. j., Heijboer; Y., Hello; J. j., Hernandez Rey; B., Herold; J., Hol; J., Hossl; C. c., Hsu; M., De Jong; M., Kadler; O., Kalekin; A., Kappes; U., Katz; O., Kavatsyuk; P., Keller; P., Kooijman; C., Kopper; A., Kouchner; I., Kreykenbohm; V., Kulikovskiy; R., Lahmann; P., Lamare; G., Larosa; D., Lattuada; D., Lefevre; A., Le Van Suu; G., Lim; D., Lo Presti; H., Loehner; S., Loucatos; S., Mangano; M., Marcelin; A., Margiotta; J. a., Martinez Mora; A., Meli; T., Montaruli; L., Moscoso; H., Motz; M., Neff; E., Nezri; V., Niess; D., Palioselitis; G. e., Pavalas; K., Payet; P., Payre; J., Petrovic; P., Piattelli; N., Picot Clemente; V., Popa; T., Pradier; E., Presani; C., Racca; D., Real; C., Reed; G., Riccobene; C., Richardt; R., Richter; C., Riviere; A., Robert; K., Roensch; A., Rostovtsev; J., Ruiz Rivas; M., Rujoiu; G. v., Russo; F., Salesa; D. f. e., Samtleben; F., Schock; J. P., Schuller; F., Schussler; T., Seitz; R., Shanidze; Simeone, Francesco; A., Spies; M., Spurio; J. j. m., Steijger; Th, Stolarczyk; A., Sanchez Losa; M., Taiuti; C., Tamburini; S., Toscano; B., Vallage; V., Van Elewyck; G., Vannoni; M., Vecchi; P., Vernin; S., Wagner; G., Wijnker; J., Wilms; E., De Wolf; H., Yepes; D., Zaborov; J. d., Zornoza; J., Zuniga. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - STAMPA. - 7:8(2012), pp. T08002-T08002. [10.1088/1748-0221/7/08/t08002]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/473489
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
55
44
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.