This study was done to evaluate the diagnostic accuracy of dual-energy X-ray absorptiometry (DXA) compared with conventional radiography for identifying vertebral fractures. A total of 930 postmenopausal women underwent conventional radiography and DXA imaging of the spine. The images were evaluated by two expert skeletal radiologists using the semiquantitative (SQ) method for conventional radiography and the morphometric vertebral fracture assessment (VFA) for DXA. The SQ method for radiography (SQ-Rx) analysed 99.1% of vertebrae, identifying 442 vertebral fractures; VFA analysed 97.5% vertebrae, detecting 420 vertebral fractures. Agreement between SQ-Rx and VFA reached 98.76%, and the kappa-score was 0.96 [95% confidence interval (CI), 0.95-0.98]. Assessing the grading of vertebral fractures, agreement reached 97.5% and the kappa-score was 0.841 (95% CI, 0.821-0.891). Considering SQ-Rx method as "gold standard", VFA had a sensitivity of 97.85 % and a specificity of 99.81%. The negative (NPV) and positive (PPV) predictive value for VFA were 99.83 % and 98.15%, respectively. Fractures were identified in 251 (27 %) and 242 (26 %) of patients on SQ-Rx and VFA, respectively. On a per-patient basis, the agreement between the two methods was 97% and the kappa-score was 0.95 (95% CI, 0.920-0.968). The diagnostic parameters for VFA were 97.23% sensitivity, 98.86% specificity, 97.60% PPV and 98.84% NPV. This study demonstrated that VFA with DXA may reach a high level of accuracy for diagnosing vertebral fractures, suggesting that VFA should be introduced in the screening of individuals with a risk of osteoporosis and in the follow-up of osteoporotic patients receiving treatment.

Vertebral morphometry by dual-energy X-ray absorptiometry (DXA) for osteoporotic vertebral fractures assessment (VFA) / Diacinti, Daniele; Guglielmi, G.; Pisani, D.; Davide, Diacinti; Argiro, R.; Serafini, C.; Romagnoli, E.; Minisola, Salvatore; Catalano, Carlo; David, Vincenzo. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 117:8(2012), pp. 1374-1385. [10.1007/s11547-012-0835-5]

Vertebral morphometry by dual-energy X-ray absorptiometry (DXA) for osteoporotic vertebral fractures assessment (VFA)

DIACINTI, Daniele;Davide Diacinti;MINISOLA, Salvatore;CATALANO, Carlo;DAVID, vincenzo
2012

Abstract

This study was done to evaluate the diagnostic accuracy of dual-energy X-ray absorptiometry (DXA) compared with conventional radiography for identifying vertebral fractures. A total of 930 postmenopausal women underwent conventional radiography and DXA imaging of the spine. The images were evaluated by two expert skeletal radiologists using the semiquantitative (SQ) method for conventional radiography and the morphometric vertebral fracture assessment (VFA) for DXA. The SQ method for radiography (SQ-Rx) analysed 99.1% of vertebrae, identifying 442 vertebral fractures; VFA analysed 97.5% vertebrae, detecting 420 vertebral fractures. Agreement between SQ-Rx and VFA reached 98.76%, and the kappa-score was 0.96 [95% confidence interval (CI), 0.95-0.98]. Assessing the grading of vertebral fractures, agreement reached 97.5% and the kappa-score was 0.841 (95% CI, 0.821-0.891). Considering SQ-Rx method as "gold standard", VFA had a sensitivity of 97.85 % and a specificity of 99.81%. The negative (NPV) and positive (PPV) predictive value for VFA were 99.83 % and 98.15%, respectively. Fractures were identified in 251 (27 %) and 242 (26 %) of patients on SQ-Rx and VFA, respectively. On a per-patient basis, the agreement between the two methods was 97% and the kappa-score was 0.95 (95% CI, 0.920-0.968). The diagnostic parameters for VFA were 97.23% sensitivity, 98.86% specificity, 97.60% PPV and 98.84% NPV. This study demonstrated that VFA with DXA may reach a high level of accuracy for diagnosing vertebral fractures, suggesting that VFA should be introduced in the screening of individuals with a risk of osteoporosis and in the follow-up of osteoporotic patients receiving treatment.
2012
conventional radiography; dxa; semiquantitative assessment; vertebral fractures; vfa
01 Pubblicazione su rivista::01a Articolo in rivista
Vertebral morphometry by dual-energy X-ray absorptiometry (DXA) for osteoporotic vertebral fractures assessment (VFA) / Diacinti, Daniele; Guglielmi, G.; Pisani, D.; Davide, Diacinti; Argiro, R.; Serafini, C.; Romagnoli, E.; Minisola, Salvatore; Catalano, Carlo; David, Vincenzo. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 117:8(2012), pp. 1374-1385. [10.1007/s11547-012-0835-5]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/465180
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 24
social impact