Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
In a 1-year multicenter study the microbial colonization of 1154 central venous catheters (CVCs) was investigated. Catheters explanted either from immunocompromised or immunocompetent patients were collected and analyzed by five clinical microbiology laboratories located in Ancona, Aviano, Catania, Pavia and Rome, Italy. A further aim was to investigate, by scanning electron microscopy, the features of currently used catheters, both new and explanted from patients, analyzing their surface quality, the influence of the host protein biofilm on their microbial colonization, the modifications caused by their permanence in the body and the relationship between these factors and the occurrence of infections.
A multicenter study on central venous catheter-associated infections in Italy / G., D., P., D.P., G., F., P., M., G., N., P. E., V., S., B., E., M., C., P., G., S., G., B., M., D.C., L., M., A., A., V., G., C., M., M., M., G., R., S., S., E., A., et al.. - In: JOURNAL OF CHEMOTHERAPY. - ISSN 1120-009X. - STAMPA. - 13:SPEC. ISS. 1(2001), pp. 251-262. [10.1179/joc.2001.13.supplement-2.251]
A multicenter study on central venous catheter-associated infections in Italy
G. Donelli;P. De Paoli;G. Fadda;P. Marone;G. Nicoletti;P. E. Varaldo;S. Bacchiocchi;E. Manso;C. Pruzzo;G. Sambo;G. Basaglia;M. De Cicco;L. Moras;A. Agodi;V. Giannino;C. Messina;M. Mezzatesta;G. Russo;S. Stefani;E. Abbaneo;E. Carretto;V. Monzillo;S. Rindi;P. Speziale;L. Visai;L. Baldassarri;M. Barbieri;V. Di Carlo;DI ROSA, Roberta;FRANCOLINI, IOLANDA;F. Ginnetti;F. Leone;P. Mazzella;MARCONI, Valter;A. Rossi
2001
Abstract
In a 1-year multicenter study the microbial colonization of 1154 central venous catheters (CVCs) was investigated. Catheters explanted either from immunocompromised or immunocompetent patients were collected and analyzed by five clinical microbiology laboratories located in Ancona, Aviano, Catania, Pavia and Rome, Italy. A further aim was to investigate, by scanning electron microscopy, the features of currently used catheters, both new and explanted from patients, analyzing their surface quality, the influence of the host protein biofilm on their microbial colonization, the modifications caused by their permanence in the body and the relationship between these factors and the occurrence of infections.
antibiotic-resistance; biofilms; bloodstream infections; catheter quality; central venous catheters; medical device-related infections; microbial colonization; scanning electron microscopy
01 Pubblicazione su rivista::01a Articolo in rivista
A multicenter study on central venous catheter-associated infections in Italy / G., D., P., D.P., G., F., P., M., G., N., P. E., V., S., B., E., M., C., P., G., S., G., B., M., D.C., L., M., A., A., V., G., C., M., M., M., G., R., S., S., E., A., et al.. - In: JOURNAL OF CHEMOTHERAPY. - ISSN 1120-009X. - STAMPA. - 13:SPEC. ISS. 1(2001), pp. 251-262. [10.1179/joc.2001.13.supplement-2.251]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/462048
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
8
31
23
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.